OBID i-scan
®
Installation
ID ISC.LRU2000
FEIG ELECTRONIC GmbH
Page 44 of 56
M60801-0de-ID-B.doc
E N G L I S H
2.7.3 Reader
synchronization
Reader synchronization can be used to synchronize various Reader actions.
Terminal
Abbreviation
Description
1
GND
GND
2
A-
- Input
3
B+
+ Input
4
Y-
- Output
5
Z+
+ Output
Table 2-9: Reader synchronization pin-outs
1
2
3
4
5
OUT+ (Z+)
OUT- (Y-)
IN+ (B+)
IN- (A-)
GND
X5
Fig. 2-8: Synchronization input and output
Summary of Contents for i-scan ID ISC.LRU2000-A-EU
Page 29: ......