OBID i-scan
®
Installation
ID ISC.LRU2000
FEIG ELECTRONIC GmbH
Page 40 of 56
M60801-0de-ID-B.doc
E N G L I S H
2.6 Supply
voltage
The supply voltage of 15 to 24 VDC is connected to Terminal X13.
Terminal
Abbreviation
Description
X13 / Pin 1
VDC
Vcc – supply voltage
X13 / Pin 2
GND
Ground – supply voltage
Table 2-5: Pin-outs for supply voltage
X13
GND
VD
C
2 1
Fig. 2-5 Connecting the supply voltage
Note:
•
Reversing the supply voltage polarity may destroy the device.