2.7.2 Relay

A relay output is provided in the form of a changeover relay.

Terminal

Abbreviation

Description

1

COM

Working contact

2

NC

Normally closed

3

NO

Normally open

Table 2-8: Relay output pin-outs

Notes:

 

The relay output is configured for max. 24 V DC / 2 A.

 

The relay output is intended for switching resistive loads only. If an inductive load is
connected, the relay contacts must be protected by means of an external protection
circuit.

ext.

U

1

2

3

X9

CO

M

NO

NC

Fig. 2-7: Internal and possible external wiring of the relay output

Summary of Contents for i-scan ID ISC.LRU2000-A-EU

Page 1: ...MONTAGE INSTALLATION final public B 2006 09 03 M60801 0de ID B doc OBID i scan ID ISC LRU2000 deutsch english...

Page 2: ...OBID i scan Montage ID ISC LRU2000 FEIG ELECTRONIC GmbH Seite 2 von 56 M60801 0de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 30 E N G L I S H...

Page 3: ...elches die in diesem Dokument be schriebenen Ger te enth lt FEIG ELECTRONIC weist ausdr cklich darauf hin dass die in diesem Dokument beschriebenen Ger te nicht f r den Einsatz mit oder in medizinisch...

Page 4: ...des Deckels 10 2 4 Anschlussklemmen 11 2 5 Antennenanschluss 12 2 6 Versorgungsspannung 12 2 7 Eing nge Ausg nge 13 2 7 1 Optokoppler 13 2 7 2 Relais 15 2 7 3 Readersynchronisation 16 2 8 Anschluss e...

Page 5: ...i scan Montage ID ISC LRU2000 FEIG ELECTRONIC GmbH Seite 5 von 56 M60801 0de ID B doc D E U T S C H 4 1 2 Netzwerkanschluss LAN 25 5 Funkzulassungen 26 5 1 Europa CE 26 5 2 USA FCC 26 6 Technische Dat...

Page 6: ...hrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs g ltigen Fassung F r eine ungeeignete falsche manuelle oder automatische Ein stellung von Parametern f r ein Ger t bzw ungeeigne...

Page 7: ...dertypen Folgende Reader und Readermodule sind z Z verf gbar Readertyp Beschreibung ID ISC LRU2000 A EU Ger tevariante mit ACC f r Europa ID ISC LRU2000 A FCC Ger tevariante mit ACC f r USA ID ISC LRU...

Page 8: ...ONIC GmbH Seite 8 von 56 M60801 0de ID B doc D E U T S C H 2 3 Montage Der Reader ist f r die Montage auf W nden auch im Freien konzipiert Zur Wandmontage befin den sich im Geh use vorgesehene L cher...

Page 9: ...gen f r die einzelnen Leitungen verwendet werden sollen 2 1 3 9 5 8 4 6 7 Bild 2 2 Montagezeichnung Kabelver schraubung Gr e Klemmbereich mm Beschreibung 1 M 16 4 5 10 Anschlusskabel Antenne 2 M 16 4...

Page 10: ...e ID ISC LRU2000 FEIG ELECTRONIC GmbH Seite 10 von 56 M60801 0de ID B doc D E U T S C H 2 3 2 ffnen des Deckels In Bild 2 3 ffnen des Deckels ist dargestellt wie sich das Geh use ffnen l sst Bild 2 3...

Page 11: ...11 von 56 M60801 0de ID B doc D E U T S C H 2 4 Anschlussklemmen J1 J2 J12 V6 X14 T1 T2 S1 J20 X13 X11 X9 X5 GND A B Y Z O C O E IN IN GND A B Y Z GND RxD TxD X12 ACC X20 X1 X2 X3 X4 X6 X7 X8 V5 V4 V...

Page 12: ...kers Klemme Beschreibung X1 X2 X3 X4 Anschluss der externen Antennen Eingangsimpedanz 50 Tabelle 2 4 Anschluss der externen Antenne 2 6 Versorgungsspannung Die Versorgungsspannung von 15 bis 24 VDC is...

Page 13: ...X6 sind galvanisch von der Reader Elektronik getrennt und m s sen daher mit einer externen Spannung versorgt werden Klemme Kurzzeichen Beschreibung 1 O C Kollektor Ausgang 1 2 O E Emitter Ausgang 1 3...

Page 14: ...r Lasten vorgesehen Optokopplereingang X6 3 4 Die Eingangs LED des Optokopplers ist intern mit einem Serienwiderstand von 500 beschaltet Bei Versorgungsspannungen gr er 10V muss der Eingangsstrom durc...

Page 15: ...M Arbeitskontakt 2 NC ffner 3 NO Schlie er Tabelle 2 8 Pinbelegung Relaisausgang Hinweise Der Relaisausgang ist f r max 24 V DC 2 A ausgelegt Der Relaisausgang ist nur zum Schalten ohmscher Lasten vor...

Page 16: ...nisation Mit der Readersynchronisation k nnen verschiedene Aktionen der Reader synchronisiert werden Klemme Kurzzeichen Beschreibung 1 GND GND 2 A Eingang 3 B Eingang 4 Y Ausgang 5 Z Ausgang Tabelle 2...

Page 17: ...r LED V1 2 V2 Anode ext Funktion entspricht interner LED V2 3 V3 Anode ext Funktion entspricht interner LED V3 4 V4 Anode ext Funktion entspricht interner LED V4 5 V5 Anode ext Funktion entspricht int...

Page 18: ...ber X8 Die bertragungsparameter k nnen per Softwareprotokoll konfiguriert werden Anschlussbelegung X8 RS232 Schnittstelle Klemme Kurzzeichen Beschreibung 1 GND RS232 GND 2 RxD RS232 RxD 3 TxD RS232 T...

Page 19: ...Schnittstellenkonfiguration mittels Jumper Der Anschluss der RS4xx Schnittstelle erfolgt ber X7 Anschlussbelegung X7 RS485 RS422 Schnittstelle Klemme Kurzzeichen Beschreibung 1 GND RS485 RS422 GND 2...

Page 20: ...Kategorie 5 verwendet werden Dies garan tiert einen problemlosen Betrieb bei 10Mbps oder 100Mbps Anschlussbelegung X8 Netzwerk Schnittstelle Klemme Kurzzeichen Beschreibung 1 TX Transmit Data 2 TX Tra...

Page 21: ...Reset im Anschluss an ein Software Update Blinkt abwechselnd mit V1 falls nach einem Reset ein Daten fehler beim Lesen der Parameter auftrat LED V3 gelb Diagnose 2 Host Kommunikation Signalisiert durc...

Page 22: ...doc D E U T S C H 3 2 Taster Schalter Kurzzeichen Beschreibung T1 Reset Taster RF Controller T2 Reset Taster ACC S1 Reserviert Tabelle 3 2 Taster Schalter T1 Durch bet tigen von T1 wird am RF Control...

Page 23: ...ration der RS485 RS422 Schnitstelle Es k nnen die eventuell ben tigten Abschlusswiderst nde mit den Jumpern J1 bis J6 zugeschaltet werden Jumper Geschlossen offen J1 Pull Up an RS4xx B ohne Pull Up an...

Page 24: ...ittstelle Bild 4 2 Jumper der RS422 Schnittstelle J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 X6 X7 Bild 4 3 Jumper der RS485 RS422 Schnittstelle Tabelle 4 3 zeigt die Standardkonfiguration der Jumper J9 b...

Page 25: ...r werksseitig die Adresse 0 eingestellt haben m ssen sie nacheinander ange schlossen und konfiguriert werden 4 1 2 Netzwerkanschluss LAN Vorraussetzung f r den Einsatz des TCP IP Protokolls ist dass j...

Page 26: ...ische Republik Slovenien Spanien Schweden Niederlande T rkei Gro britan nien Frequenzbereich nicht implementiert Estland Individuelle Lizenz ben tigt Bei Betrieb im Band I nach ERC REC 70 03 Annex 1 8...

Page 27: ...pple max 150 mV Leistungsaufnahme max 30 VA Betriebsfrequenz 869 525 MHz EN 300 220 865 6 867 6MHz EN 302 208 902 928MHz FCC CFR 47 Part 15 247 Sendeleistung 100 mW 3 W 100 mW Step Software 4 W EIRP F...

Page 28: ...eader Mode Data Filtering and buffe ring Unterst tzte Transponder 18000 6 B EPC class 1 gen 1 EPC class 1 gen 2 Signalgeber optisch 6 LEDs zur Diagnose des Betriebszustandes Umgebungsbedingungen Tempe...

Page 29: ......

Page 30: ...the subject of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability sui...

Page 31: ...s 36 2 3 2 Opening the cover 37 2 4 Terminals 38 2 5 Antenna connection 39 2 6 Supply voltage 40 2 7 Inputs Outputs 41 2 7 1 Optocouplers 41 2 7 2 Relay 43 2 7 3 Reader synchronization 44 2 8 External...

Page 32: ...scan Installation ID ISC LRU2000 FEIG ELECTRONIC GmbH Page 32 of 56 M60801 0de ID B doc E N G L I S H 4 1 2 Network connection LAN 53 5 Radio Approvals 54 5 1 Europe CE 54 5 2 USA FCC 54 6 Technical D...

Page 33: ...ptions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual...

Page 34: ...der types The following Readers are currently available Reader type Description ID ISC LRU2000 A EU Device version with ACC for Europe ID ISC LRU2000 A FCC Device version with ACC for USA ID ISC LRU20...

Page 35: ...ELECTRONIC GmbH Page 35 of 56 M60801 0de ID B doc E N G L I S H 2 3 Installation The Reader is designed for wall mount including outdoors Holes for mounting on a wall are provided in the housing Fig 2...

Page 36: ...ndicates which cable glands should be used for the individual lines 2 1 3 9 5 8 4 6 7 Fig 2 2 Installation drawing Cable gland Size Clamping range mm Description 1 M 16 4 5 10 Antenna cable 2 M 16 4 5...

Page 37: ...an Installation ID ISC LRU2000 FEIG ELECTRONIC GmbH Page 37 of 56 M60801 0de ID B doc E N G L I S H 2 3 2 Opening the cover Fig 2 3 Opening the cover shows how to open up the housing Fig 2 3 Opening t...

Page 38: ...NIC GmbH Page 38 of 56 M60801 0de ID B doc E N G L I S H 2 4 Terminals J1 J2 J12 V6 X14 T1 T2 S1 J20 X13 X11 X9 X5 GND A B Y Z O C O E IN IN GND A B Y Z GND RxD TxD X12 ACC X20 X1 X2 X3 X4 X6 X7 X8 V5...

Page 39: ...connection The external antenna is connected on the analog circuit board The maximum tightening torque for the SMA sockets is 0 45 Nm Caution Exceeding the tightening torque will destroy the plug Ter...

Page 40: ...e The supply voltage of 15 to 24 VDC is connected to Terminal X13 Terminal Abbreviation Description X13 Pin 1 VDC Vcc supply voltage X13 Pin 2 GND Ground supply voltage Table 2 5 Pin outs for supply v...

Page 41: ...s on Terminal X6 are galvanically isolated from the Reader electronics and must therefore be externally supplied Terminal Abbreviation Description 1 O C Collector Output 1 2 O E Emitter Output 1 3 IN...

Page 42: ...he output is intended for switching resistive loads only Optocoupler input X6 3 4 The input LED associated with the optocoupler is connected internally to a series resistor of 500 For supply voltages...

Page 43: ...COM Working contact 2 NC Normally closed 3 NO Normally open Table 2 8 Relay output pin outs Notes The relay output is configured for max 24 V DC 2 A The relay output is intended for switching resistiv...

Page 44: ...2 7 3 Reader synchronization Reader synchronization can be used to synchronize various Reader actions Terminal Abbreviation Description 1 GND GND 2 A Input 3 B Input 4 Y Output 5 Z Output Table 2 9 Re...

Page 45: ...node ext Function same as internal LED V1 2 V2 Anode ext Function same as internal LED V2 3 V3 Anode ext Function same as internal LED V3 4 V4 Anode ext Function same as internal LED V4 5 V5 Anode ext...

Page 46: ...cted on X8 The transmission parameters can be configured by means of software protocol Pin configuration X8 RS232 interface Terminal Abbreviation Description 1 GND RS232 GND 2 RxD RS232 RxD 3 TxD RS23...

Page 47: ...see Section Interface configuration The RS485 RS422 interface is connected on X7 Pin configuration X7 RS485 RS422 interface Terminal Abbreviation Description 1 GND RS485 RS422 GND 2 A RS485 RS422 A 3...

Page 48: ...tructured cabling Cat 5 cables should be used This ensure reliable operation at 10Mbps or 100Mbps Pin configuration for X8 network interface Terminal Abbreviation Description 1 TX Transmit Data 2 TX T...

Page 49: ...V1 after a reset following a software update Flashes alternately with V1 in case of a data error when reading the parameters after a reset LED V3 yellow Diagnostic 2 Host communication Short flashing...

Page 50: ...mbH Page 50 of 56 M60801 0de ID B doc E N G L I S H 3 2 Buttons Switches Abbreviation Description T1 RF Controller reset button T2 ACC reset button S1 Reserved Table 3 2 Buttons Switches T1 Pressing T...

Page 51: ...RS485 RS422 port Any termination resistors needed can be enabled using jumpers J1 through J6 Jumper Closed Open J1 Pull Up on RS4xx B without Pull Up on RS4xx B J2 Pull Down on RS4xx A without Pull Do...

Page 52: ...Fig 4 1 RS485 interface jumpers Fig 4 2 RS422 interface jumpers J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 X6 X7 Fig 4 3 RS485 RS422 interface jumpers shows the standard configuration of jumpers J9 throu...

Page 53: ...Reader Note Since all Readers are factory set with address 0 they must be connected and configured one after the other 4 1 2 Network connection LAN The prerequisite for using TCP IP protocol is that e...

Page 54: ...Portugal Romania Slovak Republic Slovenia Spain Sweden The Neth erlands Turkey United Kingdom Operation not currently permitted Estonia Operation only with individual license When operating the ID ISC...

Page 55: ...perating frequency 869 525 MHz EN 300 220 865 6 867 6 MHz EN 302 208 902 928 MHz FCC CFR 47 Part 15 247 Transmitting power 100 mW 3 W 100 mW Step Software 4 W EIRP FCC CFR 47 Part 15 247 2 W ERP EN 30...

Page 56: ...buffering Supported transponders 18000 6 B EPC class 1 gen EPC class 1 gen 2 Optical indicators 6 LEDs for operating status diagnostics Ambient Temperature range Operating Storage 25 C to 55 C 25 C t...

Reviews: