8
Digital Outputs of People
Counter
Setting Time:
with „Setting Time“ set
time of the outputs for
alarm duration.
(10 means 1 second)
(e.g. 10 x 100ms)
Set:
Output 1 for LED 1 of
Antenna 1 to “True”
Output 2 for LED 2 of
Antenna 2
to “True”
Output 3 for LED 3 of
Antenna 3
to “True
”
Only the LED of the antenna
which detects the
Transponder will be switched
on.
9
Set by clicking on „Apply“
10
Transponder
If the alarm should occur by
a transponder with valid AFI
byte, you have to configure
the reader as follow:
ISO-15693
– Selection Mask
Set “Enable AFI”
Set the value for the AFI in
field “AFI1” (e.g. 01)
Note:
Up to four different AFI
values could be set.
11
Operating Mode
If the alarm should occur by
an EAS, you have to
configure the reader as
follow:
Set “EAS”
12