030099-219 Rev C
Page 3 of 3
c.
Installing New Reservoir
1)
The faucet cover can be removed from the current reservoir once it is out of the
cabinet, and placed on the sanitized reservoir before installation. Do this by
unsnapping the top of the faucet cover from the valve plate, and pulling it out and up.
Follow the procedure in reverse to reinstall it.
2)
For models with a hot tank, make sure the O-ring in the reservoir and on the hot tank
manifold are lubricated with Dow Corning
®
111 Valve Lubricant & Sealant or
equivalent.
3)
D
O NOT TOUCH THE INSIDE OF THE RESERVOIR WITH BARE HANDS
. I
T MUST REMAIN
SANITARY
.
4)
Align reservoir with probe; push downward on the reservoir. You may need to tip the
reservoir slightly to feed the faucet handles past the overhang. Continue pushing
downward on the reservoir until the insulation rests on the shelf.
5)
Replace the reservoir lid and cabinet top, making sure to snap each securely in
place.
WARNING
The warranty for this machine is automatically void if any alteration, modification, or
combination with any other machine or device is deemed to be the source of any claim. The
Underwriters' Laboratory Listing and CSA's certification may be void as the result of any
alteration or modification. The manufacturer accepts no liability resulting from any alteration,
modification, or combination with any other machine or device.
E
XCEPT AS SET FORTH HEREIN
,
THE MANUFACTURER MAKES NO OTHER WARRANTY
,
GUARANTEE
,
OR
AGREEMENT EXPRESSED
,
IMPLIED
,
OR STATUTORY
,
INCLUDING ANY IMPLIED WARRANTY OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
.
Dow Corning
®
is a registered trademark of the Dow Corning Corporation
Clorox
®
is a registered trademark of the Clorox Company
OASIS
®
is a registered trademark of OASIS Corporation
“Three Palms Design” is a registered trademark of OASIS Corporation
©
Copyright 2000 OASIS Corporation