030099-219 Rev C
Page 2 of 3
6.
WARNING: A
PRESSURE REGULATOR
,
SUCH AS A SLOW FLOW REGULATOR
,
MUST BE INSTALLED
IN FRONT OF THE UNIT
’
S WATER INLET IF THE WATER PRESSURE
(
INCLUDING ANY POSSIBLE
PRESSURE SPIKES
)
COULD EXCEED
100
PSIG
(690
KPG
).
a. Turn on water supply to cooler.
b. Check the available power supply against the water cooler data plate to assure correct
electrical service. Plug power supply cord into receptacle.
7.
CAUTION: O
N MODELS WITH A HOT TANK
,
THE HOT TANK SWITCH MUST BE IN THE
“OFF”
POSITION
. S
WITCH IS MOUNTED ON THE COLUMN SUPPORT INSIDE THE ACCESS DOOR
.
a. After the reservoir is full, check all connections for leaks.
b. Open each faucet until water flows freely.
c. On models with a hot tank, turn on the hot tank by depressing the switch toward the
“RESET” position.
8.
CAUTION: F
AILURE TO FILL HOT TANK WITH WATER BEFORE TURNING ON THE HOT TANK CAN
CAUSE PHYSICAL DAMAGE TO THE UNIT
.
9.
CAUTION:
WATER FROM HOT FAUCET CAN SCALD
.
10.
SAFETY FLOAT --
The cooler is equipped with a safety float to prevent overfilling in case
the fill float fails. If the fill float should fail, the safety float will be activated as the water
level rises. When the safety float is activated, water flow to the reservoir will be shut off.
Press the blue reset button about half way down on the reservoir lid until you hear the
water flow restart, then call your service representative
. CAUTION: A hard impact or
jarring of the unit while it is filling may trip the safety float.
11.
TO DISCONTINUE USE OF WATER COOLER
a. Shut off water supply to cooler.
b. On models with a hot tank, place hot tank switch in the “OFF” position. Draw water from
hot faucet until water is cool.
c. Disconnect power supply cord.
d. Drain reservoir through cold faucet.
e. On models with a hot tank, drain tank by placing a container under black drain valve
located on the condenser. Turn drain valve counter clockwise to open, and catch water
in container. OR, for convenience, insert one end of a 3/8” OD tube into the opening of
the drain valve and the other into a container and drain. Close drain valve when the
tank is empty.
f.
A
LWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED OR BEFORE
SHIPPING THE WATER COOLER
.
12.
REMOVABLE RESERVOIR --
The cooler is designed with a removable reservoir. The
reservoir can be replaced with a sanitized unit during routine maintenance services.
a. To Remove Reservoir
1)
Drain the cooler as described in Step 7.
2)
Remove the top by lifting it up and pressing in on the cabinet back. The best
location to press is about 4” (100mm) in from either side, and 2” (50mm) from the
top. This will help release the snapping mechanism.
3)
Remove the reservoir lid by pushing down slightly near the lid center and lifting on
each tab at the front of the lid. Once loose, lift on each of the other two corners so
the lid lifts up as straight as possible.
4)
Grasp the top of the reservoir using the handholds and pull slightly upward in a
straight motion. There will be some resistance due to the sealing around the probe.
Gently push the faucet handles in as you lift until they clear the cabinet overhang.
b.
CAUTION: T
HE HOT FAUCET SAFETY HANDLE IS ESPECIALLY PRONE TO CATCH ON THE
OVERHANG
.