background image

6.2 Func

ti

ons of the Controller

6.2.1 Start-up & Shutdown

Only from the main screen, the unit can be turned on of o

. If the half or full-o

screen appears, press any key to go

back to the main interface.

When the unit is started using the controller, if the emergency switch was used to shut it down the controller will
display as follows; the opera

ti

on will be the same as the regular ON/OFF screen.

6.2.2 Switching Modes

To switch modes, from the main menu short press the MENU bu

tt

on to choose from Hea

ti

ng, Cooling or Auto

modes. A symbol will display on the controller according to what mode is ac

ti

ve. A

ft

er 2 seconds without a change,

the se

tti

ng will be saved.

If the unit is defros

ti

ng, the defros

ti

ng symbol will display on the main interface. A

ft

er defros

ti

ng is complete, the

unit automa

ti

cally switches to Hea

ti

ng or Auto mode depending on what was on prior to defros

ti

ng. Under

defros

ti

ng the mode can be switched however the unit won’t apply the mode un

ti

l defros

ti

ng has been completed.

6.2.3 Se

tting

the Target Temperature

From the main menu, press the UP or DOWN keys to adjust the temperature se

tti

ng as desired. If you press the

ON/OFF bu

tt

on during this, you will be taken back to the main menu with no changes saved. If there is no opera

ti

on

for 5 seconds or the MODE bu

tt

on is pressed, the adjustments to the temperature will be saved and you will return

to the main menu.

1 7

11

Summary of Contents for I Series

Page 1: ...oasis i series Inverter Pool Heat Pump Installation Operation Manual oasisheatpumps com...

Page 2: ......

Page 3: ...Contents 1 1 1...

Page 4: ...sts Designed with the latest technology including stepless full DC inverter compressors fans and control systems the Oasis I series is the energy e cient and environmentally friendly way to enjoy a lo...

Page 5: ...ater Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight Nominal Heating Capacity kW Btu h kW Btu h kW kW A A W RPM dB...

Page 6: ...onnection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight Nominal Heating Capacity kW Btu h kW Btu h kW kW A A W RPM dB A mm 3...

Page 7: ...ection Noise Water Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight kW Btu h kW Btu h kW kW A A W RPM dB A mm m 3 h...

Page 8: ...2 Unit Dimensions Unit mm 545 1000 398 Oasis I9 I12 6...

Page 9: ...Oasis I17 1046 101 453 615 767 Water inlet 40 Water outlet 40 96 790 490 862 466 1160 Oasis I19 7 1 1...

Page 10: ...Oasis I25 Oasis I29T 8 Water inlet 40 Water outlet 40 96 790 490 862 466 1160...

Page 11: ...r the feet of the unit 3 Install the supplied condensation barb to the underside of the unit and direct the condensation to an appropriate drainage point PLUMBING INSTALLATION PLEASE NOTE Oasis heat p...

Page 12: ...ithin 60seconds 4 To select the operating mode press the M button to cycle to the sun icon heating 5 To set the temperature press in the main interface the current target temperature will ash 6 Press...

Page 13: ...ent device RCD having a rated residual operating current not exceeding 30mA and disconnection must be incorporated in the xed wiring in accordance with the wiring rules The unit should be installed op...

Page 14: ...ill void the warranty Correct installation is required to ensure safe and e cient operation of your pool heater Before installation it is very important to ensure 5 variables are carefully checked to...

Page 15: ...ter de ector may be needed to protect the heat pump If installing the heater on an exis ng pump ltra on system the heater must be installed AFTER the lter and BEFORE the chlorinator sani zer The heat...

Page 16: ...p 5 6 Rubber Feet All Oasis units are provided with rubber feet which we highly recommend being installed The rubber feet help reduce vibration of the unit and help provide a space below the heat pump...

Page 17: ...connecting Ensure the power cable and circuit breaker are of a suitable size for the heater being installed Also check that there is adequate voltage and current available at the heater connection to...

Page 18: ...Heating mode is active FAULT Displays when a fault occurs AUTO Auto mode is active WIRELESS Appears if the unit is connected to wi and shows the strength of the signal accordingly DEFROSTING Unit is...

Page 19: ...ctive After 2 seconds without a change the setting will be saved If the unit is defrosting the defrosting symbol will display on the main interface After defrosting is complete the unit automatically...

Page 20: ...peration for 20 seconds the system will automatically memorise the settings and return to the main menu Press the ON OFF button at any time during changes to exit without saving changes 6 2 5 Timer Se...

Page 21: ...click silent function If the one click silent and timing silent function are both started at the same time press MUTE to cancel the one click silent unction and quit the timing silent functions At nig...

Page 22: ...u hold the ON OFF button for around 5 seconds The keyboard will be locked when the small lock symbol appears The screen can be locked while the controller is in the on or o interface Under the locked...

Page 23: ...water system is jammed or not Low temperature protection Non The environment temp is low Comp Overcurrent Prot E051 The compressor is overload Check whether the system of the compressor running normal...

Page 24: ...2 2...

Page 25: ...able of Refrigerant SaturationTemperature Pressure MPa 0 0 3 0 5 0 8 1 1 3 1 5 1 8 2 2 3 Temperature R410A C 51 3 20 9 4 11 19 24 31 35 39 Temperature R32 C 52 5 20 9 3 5 10 18 23 29 5 33 3 38 7 Press...

Page 26: ...24 7 6 Interface Drawing 1 Main Board 1 2 4 5 6 3 1 2 3 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 1 2 1 2 1 2 4 5 6 3 1 2 1 2 1 2 1 2 1 2 4 5 6 3...

Page 27: ...or 4 way valve Water pump Compressor signal DC motor reserved Program download interface Color line controller communication The port for centralized control Electronic expansion valve resistance resi...

Page 28: ...C1004 G CN9 12 0 10V_OUT PWM_OUT PWM_IN GND GND GND GND 5V AI DI13 GND GND 485_B1 485_A1 12V CN13 CN8 CN2 1 2 3 4 5 1 2 3 T5AL250V GND 485_B2 485_A2 12V FUSE 2 1 4 3 2 1 4 3 GND 485_B3 485_A3 12V 2 1...

Page 29: ...of the input and output interface instructions below Number Sign Meaning Color line controller communication Wifi module DC fan module Coil temperature input Mode switch input Frequency conversion boa...

Page 30: ...egularly Check the water inlet outlets often for leaks You should avoid the condition of no water or air entering into the system as this will in uence unit s performance and reliability You should cl...

Page 31: ...luding cigarette smoking should be kept su ciently far away from the site of installation repairing removing and disposal during which ammable refrigerant can possibly be released to the surrounding s...

Page 32: ...l point to warn of a potentially hazardous situation 2 Particular attention shall be paid to the following to ensure that by working on electrical components the casing is not altered in such a way th...

Page 33: ...The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be ushed with OFN to render the unit safe This process may need to be repeated several times Compressed...

Page 34: ...trically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerantcylinders All personal protective equipment is available and being...

Page 35: ...rceived problem is explained within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Oasis in NZ or S...

Page 36: ...rst Dr Knox eld VIC 3180 T 03 9887 2131 New South Wales Unit 1 20 22 Foundry Rd Seven Hills NSW 2147 T 02 9838 0000 Queensland Unit 4 8 Reichert Dr Molendinar QLD 4214 T 07 5679 6821 South Australia S...

Reviews: