MAINTENANCE FUNDAMENTALS, CONT

D: HONEYCOMB AIR DIFFUSERS

 

7. Honeycomb Maintenance

 

 

Preventive maintenance should be performed every 

30 days unless conditions warrant a more frequent 

replacement cycle.

 

 

Honeycomb Air Diffuser Removal

 

 

Honeycomb is located in discharge air duct.

 

 

A. Wedge a non

-

metallic device of suitable strength (such 

as a ballpoint pen) between the honeycomb and the end 

panel.

 

Caution! Use care not to dislodge the heating wire (that 

prevents condensation on the lamp assembly).

 

B. Apply pressure to collapse the honeycomb to allow it to 

be pulled out of honeycomb retainer.

 

C. Pry downward and away from honeycomb retainer.

 

 

• 

Clean honeycomb with warm water and soap solution.

 

• 

Submerse if necessary.  

 

• 

Use brush to dislodge stubborn or sticky residue.  

 

• 

Dry by using vacuum

s blow mode (vs. suction mode).  

 

 

Honeycomb Air Diffuser Installation

 

 

D. Squeeze honeycomb to allow it to fit into honeycomb 

retainer.

 

E. Carefully slide honeycomb into place.

 

F. Adjust honeycomb so that it fits flat against retainer.      

It must not be wavy or out of position.

 

 

Note: For honeycomb air diffusers in other locations, 

these same general instructions apply.

 

A

 

B

 

C

 

D

 

E

 

F

 

 Note: Model features and options may vary.

 

Honeycomb

 

Air Diffuser

 

Summary of Contents for CO2739R

Page 1: ...USER MANUAL_CO2739R_REF_SVC SELF SVC_SELF CONT_CASE Model CO2739R Shown With Product For Illustrative Purposes Only READ AND SAVE THESE INSTRUCTIONS SCC P N 99399 USER MANUAL Oasis Structural Concepts...

Page 2: ...LUG LED LIGHTS FIXTURES MAINTENANCE FUNDAMENTALS CONTINUED HONEYCOMB AIR DIFFUSERS ELECTRICAL FUNDAMENTALS REFRIGERATION FUNDAMENTALS SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE TROUBLE...

Page 3: ...CE Performance issues when in violation of applicable NEC federal state and local electrical and plumbing codes are not covered by warranty See below compliance guideline WARNINGS This sheet contains...

Page 4: ...oved by Structural Concepts and Structural Concepts attests under penalty of perjury that these statements are true and accurate CAUTION DO NOT RELY ON THERMOMETERS OR THERMOSTATS FOR PRODUCT FOOD TEM...

Page 5: ...n position and level and plumb if case has levelers you must reattach these components to case 3 Remove Case From Skid To prevent damage support case while sliding it toward edge of skid For units wit...

Page 6: ...m inside of the case check for discharge air from front baffle to confirm that the fans are functioning properly When the case is in a start up mode or has been idle for a long period of time Main Pow...

Page 7: ...lle 3 Light Fixtures Fluorescents Removal of lamp Rotate lamp 1 4 turn either direction to disengage upper or lower pins contacts from lamp mounting sockets Remove bulb buy applying even pressure from...

Page 8: ...fully pull away from its spring Disconnect plug from LED s socket Contact Structural Concepts Technical Service Department for replacement parts see Technical Service section of this manual for inform...

Page 9: ...sure to collapse the honeycomb to allow it to be pulled out of honeycomb retainer C Pry downward and away from honeycomb retainer Clean honeycomb with warm water and soap solution Submerse if necessar...

Page 10: ...Access and Connections Warning disconnect power before providing maintenance and service to unit 2 Light Ballast Access Remove three screws from the rear wire channel Remove four screws from the rear...

Page 11: ...lower decking A finger hole is provided to assist in lifting up and pulling out deck 3 Expansion Valve Access Remove lower decking A finger hole is provided to assist in lifting up and pulling out dec...

Page 12: ...0 16 A R513A AMOUNT 50 OZ HIGH 186 LOW 88 20A 20A Super Heat Temp 6 8 F FOR PARTS AND SERVICE Defrost 6 defrosts per day 45 F CALL 1 800 433 9490 Serial Label Location Information Listed Technical Inf...

Page 13: ...rcuits Temperature Controller Has No Illumination Check connections on power supply contactor board Check fuse on power supply contactor board Fans Not Working Check that the power is on Check that fa...

Page 14: ...system Check that liquid line filter dryer is not plugged Check that close offs are intact around condensing coil and that air is not recirculate Check that store ambient temperature isn t above maxi...

Page 15: ...e is no air recirculation around evaporator coil Check that evaporator coil is not iced up High Suction Pressure Check for refrigerant overcharge Check that compressor reed valves aren t bad Look for...

Page 16: ...16 ILLUSTRATED PARTS BREAKDOWN 4 8 2 6 7 15 13 5 3 14 9 1 17 12 11 10 16...

Page 17: ...Panel 11 Wire Channel 3 End Panel Mirror 12 Rear Grille 4 Air Deflector Glass 13 Temperature Controller 5 Single Pole Switch 14 Fan Motor Evaporator 6 Front Panel 15 Deck Pan 7 Bumper Insert 16 Lamp B...

Page 18: ...ove rear doors and clean with a household or commercial cleaner X Vacuum tub under deck or soap and water if necessary To flush out the tub disconnect power to the case Remove the ABS deck and the fan...

Page 19: ...s Used OnYour Case Follow These Instructions If Viewing This Document on Smart Phone Tablet or Computer Select Click On The QR Code at Right If Viewing This Document In Print Hard Copy Scan The QR Cod...

Page 20: ...LLOWING INFO AVAILABLE BEFORE CONTACTING STRUCTURAL CONCEPTS SERIAL NO MODEL NO STORE NO STORE ADDRESS DETAILS PHOTOS LEAK LOCATIONS DAMAGE STORE S AMBIENT CONDITIONS ETC ToAccess The Limited Warranty...

Reviews: