V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
[email protected]
oasisaquatics.com.au
13
FAULT CODES
Blinks
Fault
Cause
1
Micro Controller Failure
Micro Controller is continually rebooting
2
Mains Under Voltage
The mains voltage has dropped below 180 volts AC running.
NOTE: If this fault is active the controller will reboot after
voltage comes above 209 volts AC for at least 6
3
Temperature
Over Temperature (100 degrees Celsius)
Under Temperature (-20 degrees Celsius)
Under abnormally high ambient operating conditions the
controller reduces the motor speed gradually in 10 rpm
increments to maintain the devices temperatures within limits.
If the speed drops to below 2410 rpm the controller shuts the
motor down and display the fault code
4
Over Current Trip
Over current protection has tripped
The speed of the motor will be adjusted down automatically
when the overload condition occurs to protect the devices. The
controller will only display this fault code when it has been
damaged.
5
Mains Over Voltage
The Mains voltage has risen above 269 volts AC
6
Output Shaft Seized
Motor failed to start
Motor was stopped
7
Self-Check
One or more of the self-tests failed at start up or while running
8
Motor Fault
One or more of the phases has become disconnected
10
Other Fault
Any fault not covered by other codes
Presently no faults should trigger this
none
EEPROM Load Failure
Checksum failed while loading EEPROM to memory
PLEASE NOTE
•
If the pump is hard wired, a qualified electrician should remove the wiring.
•
Barrel unions need to be hand tightened. No sealant, glues or silicones are required.
•
When making any enquiries about your OASIS pool and spa pump be certain to quote the
model number from the nameplate located on motor.
•
Never run pump dry. Running the pump with no water may damage the mechanical seals,
causing leakage and flooding. Dry running damage and associated damage is not covered
under warranty.
•
Failure to undertake regular maintenance may cause damage not covered by warranty.
•
The pump is not intended for use by young children or infirm persons without supervision.
Ensure that young children are supervised at all times to ensure that they do not play with
the pump.