FAULT CODES

 

Blinks 

Fault 

Cause 

Micro Controller Failure 

Micro Controller is continually rebooting 

Mains Under Voltage 

The mains voltage has dropped below 180 volts AC running. 
NOTE:  If  this  fault  is  active  the  controller  will  reboot  after 
voltage comes above 209 volts AC for at least 6 

Temperature 

Over Temperature (100 degrees Celsius) 
Under Temperature (-20 degrees Celsius) 

Under  abnormally  high  ambient  operating  conditions  the 
controller  reduces  the  motor  speed  gradually  in  10  rpm 
increments to maintain the devices temperatures within limits. 
If the speed drops to below 2410 rpm the controller shuts the 

motor down and display the fault code 

Over Current Trip 

Over current protection has tripped 
The  speed  of  the  motor  will  be  adjusted  down  automatically 
when the overload condition occurs to protect the devices. The 

controller  will  only  display  this  fault  code  when  it  has  been 
damaged.  

Mains Over Voltage 

The Mains voltage has risen above 269 volts AC 

Output Shaft Seized 

Motor failed to start 
Motor was stopped  

Self-Check 

One or more of the self-tests failed at start up or while running  

Motor Fault 

One or more of the phases has become disconnected  

10 

Other Fault 

Any fault not covered by other codes 
Presently no faults should trigger this 

none 

EEPROM Load Failure 

Checksum failed while loading EEPROM to memory 

 

PLEASE NOTE

 

 

If the pump is hard wired, a qualified electrician should remove the wiring.  

 

Barrel unions need to be hand tightened. No sealant, glues or silicones are required. 

 

When making any enquiries about your OASIS pool and spa pump be certain to quote the 
model number from the nameplate located on motor. 

 

Never run pump dry. Running the pump with no water may damage the mechanical seals, 
causing leakage and flooding. Dry running damage and associated damage is not covered 
under warranty. 

 

Failure to undertake regular maintenance may cause damage not covered by warranty. 

 

The pump is not intended for use by young children or infirm persons without supervision. 
Ensure that young children are supervised at all times to ensure that they do not play with 
the pump. 

 

 

Summary of Contents for V Series

Page 1: ...ON AND OPERATION MANUAL V SERIES Variable 3 Speed Pool Spa Pump V SERIES V310 V390 V480 Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T 03 9887 2131 New South Wales Unit 1 20 22 Foundry Road Seven...

Page 2: ...BEFORE OPERATING Please pass these instructions on to the owner of this equipment V310 1 25HP V390 1 75HP V480 2 25 HP DANGER HAZARDOUS SUCTION Do not block water entry into filtration system with an...

Page 3: ...rical equipment is in good condition Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discovered Do not add chemicals directly to the pool skimmer Adding und...

Page 4: ...pool and spa pump is thoroughly water tested against flow pressure voltage current and mechanical performance parameters OASIS S advanced pump technology provides reliable and efficient performance t...

Page 5: ...OTECTION It is recommended that the pump be protected from the weather Enclosures should be ventilated to allow a free flow of air for the fan cooled motor POWER CONNECTION OASIS pool and spa pumps ar...

Page 6: ...tlet piping from the pump should be connected to the inlet connection on the swimming pool filter at the filter valve For pump installations above water level it generally requires a check valve in th...

Page 7: ...et lid and filling the strainer basket area with water Replace the lid ensuring that it seals on the large o ring 2 Connect to the power supply and switch on 3 Allow the pump to run so that any air tr...

Page 8: ...ATION AND OPERATION MANUAL info oasisaquatics com au oasisaquatics com au 8 FACTORY SETTING SPEEDS STAR RATINGS V310 7 Star Low 1600 Medium 2400 High 2850 V390 7 Star Low 1450 Medium 2400 High 2850 V4...

Page 9: ...ncrease the speed setting This setting is not recommend to be used with a suction cleaner but may work 2 Med This should be used for gentle spa jet action and the majority of suction cleaners when con...

Page 10: ...d to a skimmer box 3 High This should be used for backwashing manual vacuuming of the pool spa jets infloor cleaning and or water features PLEASE NOTE The V SERIES V390 will always run at high speed f...

Page 11: ...t pot strainer basket lid anti clockwise and remove 3 Remove the hair and lint pot strainer basket by lifting upwards from its housing 4 Empty the trapped refuse from the basket Hose out with water if...

Page 12: ...entre at the address indicated in this manual If the pump runs but there is no water flow or water flow is reduced the following condition may apply 1 The filter requires backwashing or it is blocked...

Page 13: ...it has been damaged 5 Mains Over Voltage The Mains voltage has risen above 269 volts AC 6 Output Shaft Seized Motor failed to start Motor was stopped 7 Self Check One or more of the self tests failed...

Page 14: ...from the date of purchase Oasis assumes no liability for consequential damages of any kind PLEASE NOTE This literature is not a complete guide to product usage Further information is available from yo...