background image

Oasis SmartChem - INSTALLATION AND OPERATION MANUAL 

 

 

 

 

 

 

Page 

11

 of 

22

 

 

Chemical Balance 

The other new menu option is Chemical Balance. (See the App Menu on 
page 7) 

• 

In this menu option you will be able to adjust your set levels for both 
pH  and  ORP.  Both  of  these  levels  can  be  adjusted  by  either 
dragging the set point or by tapping along the Set Point line. 

• 

Underneath the Set Point line will be displayed what the Acid Pump 
is doing. For instance (as displayed to the right); the Acid pump is 
in its waiting cycle after dosing, to take a future reading to see if it 
needs to dose again. It is also displaying the last time that it dosed. 

• 

The Prime button allows you to cycle the Acid Dosing pump for 10 
seconds to get the pump primed and to ensure that it is working. 
After you press the priming button, it will give you a 10 second count 
to let you know how much time is left for the priming cycle. 

 

The following is displayed on the App Home Screen. 

There is only a limited amount of information displayed in regards to the 
Chemical Balance information. 

It displays whether the pH is Low, Normal or High. 

The ORP will also display whether it is Low, Normal or High. 

On the right-hand  side  of the  box there  is  a  plus  (+)  symbol  that  when 
tapped, will allow the Chemical balance window to be expanded. 

 

 

 

 

Once  the  Chemical  Balance  display  window  is  expanded,  the  window 
displays the following.  

With the pH highlighted, the Chemical Balance window will display; 

1. 

Whether the pH is Low, Normal, or High. 

2. 

What the actual pH level is currently. 

3. 

What the Set Point for pH is set to achieve. 

NOTES: 

• 

A low pH reading indicates that the pool water has become Acidic. This 
can lead to skin and eyes being irritated during swimming. 

• 

A high pH reading indicates that the pool water has become Alkaline. 
This makes it harder for the Chlorine to kill the germs in the pool water. 

 

 

 

 

Summary of Contents for SmartChem

Page 1: ......

Page 2: ...2 GENERAL OVERVIEW 3 3 INSTALLATION 4 Mounting 4 Installation Diagram 4 Base Plate 6 Controller Connection 8 App Setup 9 4 ANCILLARY INSTRUCTIONS 13 Maintenance Schedule 13 Probe Cleaning 14 Replacin...

Page 3: ...L CALCIUM HARDNESS 90 300 mg L PHOSPHATE FREE 0 TOTAL DISOLVED SOLIDS Below 1500ppm Always take a sample of your pool water away from the return jets to ensure as accurate reading as possible Always s...

Page 4: ...m will automatically dose Pool acid when it is required to maintain the set pH level The Oasis SmartChem will also maintain the systems ORP by either turning the Chlorinator On or Off or by automatica...

Page 5: ...red if installing into 40mm pipe for the sensors to mount into the centre of the inputs will be drilled out to accommodate the sensor probes A power cable providing power to the Oasis SmartChem from a...

Page 6: ...or a period of time to ensure the glue used to connect the manifolds has had the appropriate time to dry and bond properly to achieve correct pressure rating The Sensor Injection Manifolds suit 50mm p...

Page 7: ...Soak the ends of supply and injection hoses in hot water for 30 seconds to soften them this will make it easier when fitting the tubes to the pump barbs The lid kit has been installed into the bottle...

Page 8: ...piping from the breather port on the lid to outside of the shed or shelter A through shed connection is supplied to prevent a build up of fumes inside the shed shelter ENSURE THAT THE OASIS SMART CON...

Page 9: ...to be utilised through the App go to page 7 Of this guide and you can exit the menu by pressing the Menu button or if you need to reset the Oasis SmartChem unit press Enter and see below for further i...

Page 10: ...first going into the Chemical Setup menu option first Chemical Setup When you go into the Chemical Setup option in the menu you will see this display The first thing that you will need to do is tell t...

Page 11: ...problem with the pump you are changing over the acid bottle tub or if you have run out of Acid The same functionality applies to the ORP Sensor The Offset will allow you to adjust the reading of the p...

Page 12: ...nd count to let you know how much time is left for the priming cycle The following is displayed on the App Home Screen There is only a limited amount of information displayed in regards to the Chemica...

Page 13: ...is displaying CHECK you will need to take a sample of your pool water to your local pool shop and get it tested and add the amount of Acid or Buffer required to get the pH level back to where it needs...

Page 14: ...page 8 of this manual Check all tubes fittings and connections to ensure no leaks Check the squeeze tube in the Peristaltic pump to ensure that it isn t leaking replace if doing so Apply a silicon lu...

Page 15: ...uted on a soft cloth Clean the pH membrane rinse with water and condition in 20 KCl before use In the case of protein contamination use 5 Pepsin in 0 1M HCl solution HINT Calibrate the pH probe regula...

Page 16: ...gently but firmly lift the cover The head cover will come off to expose the squeeze tube and the head The pump head can be pulled out the squeeze tube will come with it and a new squeeze tube can be...

Page 17: ...rectly Clean and or Re calibrate probe or adjust probe Offset as per pg 8 pH Set Point is set to High Adjust pH Set Point to appropriate level 7 2 7 8 Manual Overdosing of Chlorine Shock Treatment Mai...

Page 18: ...ppropriate level 30 50mg L As per above Note The need to run Stabiliser in an outdoor pool may be reduced if your Chlorinator is sufficiently sized to produce enough chlorine to negate the use of Stab...

Page 19: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 18 of 22...

Page 20: ...c to 14 strongly alkaline but any reading outside of the 5 5 to 8 5 range will only be displayed in the Chemical Setup option of the menu ORP readings on the home screen of the Oasis Smart App will on...

Page 21: ...e interval of time for the added chemicals to properly mix throughout the pool system Continue testing and adding chemicals until the pool system becomes balanced o If you add large quantities of chem...

Page 22: ...breach of a condition or warranty shall be limited to replacing or acquiring the equipment or part thereof where the same has been supplied The maximum liability incurred by the manufacturer shall no...

Page 23: ...subject s Its use is beyond the control of the author contributor publishers and distributors and should not be relied upon without consulting your local Professional for comprehensive advice This gui...

Page 24: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 23 of 22 9 NOTES...

Page 25: ...eld VIC 3180 Australia T 03 9887 2131 New South Wales Unit 2 10 Boden Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland Unit 4 8 Reichert Drive Molendinar QLD 4214 Australia T 07 5679 6821...

Reviews: