- EN -
11
Wear parts
Impeller
(20)
and foam filters
(7)
are wearing parts and are, therefore, not covered by our warranty.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Clean the unit thoroughly, check for damage and
store immersed in a frost-free environment. Ensure that the power plug is not flooded.
Remedy of faults
Malfunction Cause
Remedy
The unit does not switch on
No mains voltage
Check mains voltage
Air in the pump housing
Pull the power plug; for venting, tilt the unit to-
wards the skimmer flap
Insufficient delivery rate
Impeller blocked
Clean
Filter basket soiled
Clean
No aeration
Air hose kinked or disconnected
Ensure secure fastening and avoid kinks in the
air hose
The air hose is not inserted up to the mark in
the intake socket
Correctly position the air hose in the intake
socket
Unit switches off after a brief running time (ap-
prox. 10 s)
Water temperature too high
Note maximum water temperature of +35°
Pump run dry
Clean pump and unit For switching on again,
pull the power plug and reinsert in the socket
The unit floats up
Filter basket full or clogged
Switch off the unit and clean filter basket
Unit floats up, pump is switched on
Impeller soiled
Switch off the unit and clean impeller
Disposal
Dispose of the unit in accordance with the national legal regulations.
Summary of Contents for SwimSkim 50
Page 1: ...23418 01 16 SwimSkim 50 23418_GAW_SwimSkim_50_A5_end_ 07 01 16 10 24 Seite 2...
Page 2: ...2...
Page 3: ...3...
Page 79: ...BG 79 20 7 10 35 C...
Page 83: ...UK 83 20 7 10 35 C...
Page 87: ...RU 87 20 7 10 35 C...
Page 91: ...CN 91 20 7 10 35 C...
Page 94: ...94...
Page 95: ......
Page 96: ...23418 01 16...