14 

ProMax MudDrain 7000/11000/14000 

 

 

 

MAINTENANCE AND CLEANING 

 

W A R N I N G  

Dangerous electrical voltage! 

Death or severe injury from electrocu-
tion. 

 

Before reaching into the water, switch 
off the mains voltage of all units in the 
water. 

 

Isolate the unit (disconnect from the 
power supply) before carrying out any 
work on it. 

 

 

N O T E  

Recommendation on regular cleaning: 

 

Clean the unit as required but at least 
twice per year. 

 

 

Do not use aggressive cleaning agents 
or chemical solutions as they could at-
tack the housing or impair the function 
of the unit. 

 

Recommended cleaning agent for re-
moving stubborn limescale deposits: 
–  Pump cleaning agent PumpClean 

from OASE. 

–  Vinegar- and chlorine-free household 

cleaning agent.  

 

After cleaning, thoroughly rinse all parts 
in clean water. 

 

WEAR PARTS 

Wear parts are excluded from the war-
ranty. 
The following components are wear parts 
and may only be replaced by the OASE 
Service. 

 

Impeller 

 

STORAGE/OVER-WINTERING 

The unit is not frost-proof and has to be 
removed and put into storage if minus 
temperatures are expected. 
How to correctly store the unit: 

 

Drain the unit as far as possible, clean 
thoroughly and check for damage. 

 

Empty all hoses, pipes and connections 
as far as possible. 

 

Thoroughly clean the unit, check it for 
damage and replace any damaged 
parts. 

 

Store the unit in a dry and frost-free 
place. 

 

Do not immerse plugs in water. 

 

DISPOSAL 

Do not dispose of this unit with domestic 
waste! For disposal purposes, please use 
the return system provided. Render the 
unit unusable beforehand by cutting the 
cables. 

 

Summary of Contents for promax cleardrain 14000

Page 1: ...ProMax MudDrain 7000 11000 14000 ...

Page 2: ...2 ProMax MudDrain 7000 11000 14000 A POX0008 B POX0013 C D POX0010 POX0011 ...

Page 3: ... 3 E POX0009 ...

Page 4: ... Additional information A Reference to a figure e g Fig A Reference to another section PRODUCT DESCRIPTION Overview A ProMax Mud Drain 7000 11000 14000 1 Handle adjustable 2 Pump base 3 Float switch 4 Connection pressure side G1 5 Power connection cable 6 Stepped hose adapter Intended use ProMax MudDrain 7000 11000 14000 re ferred to in the following as unit may only be used as specified in the fo...

Page 5: ...e Only plug the unit into a correctly fitted socket Safe operation Dangerous electrical voltage Possible death or severe injury from electrocu tion Before reaching into the water al ways switch off and disconnect isolate all units located in the water with a volt age of 12 V AC or 30 V DC and se cure them from being switched on again Only operate the unit if no persons are in the water Never opera...

Page 6: ...s function ensure that the length of cable between the float switch and the cable clip measures at least 10 cm N O T E The minimum residual water height is only reached in manual mode Manual mode The pump remains permanently switched on if the float switch is set vertically and the cable points downward N O T E The pump can run dry in manual mode Switch off the pump when the minimum water level is...

Page 7: ...se this will impair the operat ing life of the unit accordingly N O T E Rinse the pump with clean water after use REMEDY OF FAULTS Malfunction Cause Remedy Pump does not start Power supply interrupted Check the fuse and electri cal plug connections Pump switches off after a short running period Overload protection has switched the pump off due to overheating Clean the intake and pressure hose Allo...

Page 8: ...and chlorine free household cleaning agent After cleaning thoroughly rinse all parts in clean water WEAR PARTS Wear parts are excluded from the war ranty The following components are wear parts and may only be replaced by the OASE Service Impeller STORAGE OVER WINTERING The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store ...

Page 9: ...tion pressure side G1 G1 G1 Minimum switch on height maximum switch off height mm 500 250 530 270 530 270 Maximum switch on height minimum switch off height mm 670 120 700 100 700 100 Flow rate max l h 7500 11500 14500 Head height max m 5 7 11 Immersion depth max m 7 7 7 Particle size max mm 30 30 30 Power connection cable Length m 10 10 10 Dimensions Length mm 193 193 193 Width mm 247 247 247 Hei...

Page 10: ...POX0039 ...

Reviews: