SAFETY INFORMATION 

This unit can be used by chil-
dren aged 8 

and above and by 

persons with reduced physical, 
sensory or mental capabilities 
or lack of experience and 
knowledge if they are super-
vised or have been instructed 
on how to use the unit in a safe 
way and they understand the 
hazards involved. 
Do not allow children to play 
with the unit. 
Only allow children to carry out 
cleaning and user maintenance 
under supervision. 

Electrical connection 

 

Only connect the unit if the electrical 
data of the unit and the power supply 
coincide. The unit data is to be found on 
the unit type plate, on the packaging or 
in this manual. 

 

Ensure that the unit is fused for a rated 
fault current of max. 30

mA by means of 

a fault current protection device. 

 

Extension cables and power distributors 
(e.g. outlet strips) must be suitable for 
outdoor use (splash-proof). 

 

Protect the plug connections from mois-
ture. 

 

Only plug the unit into a correctly fitted 
socket. 

Safe operation 

 

Dangerous electrical voltage. Possible 
death or severe injury from electrocu-
tion! Before reaching into the water, al-
ways switch off and disconnect (isolate) 
all units located in the water with a volt-

age of >12

V

AC or >30

V

DC and se-

cure them from being switched on 
again. 

 

Only operate the unit if no persons are 
in the water. 

 

Never operate the unit if either the elec-
trical cables or the housing are defec-
tive! 

 

Do not carry or pull the unit by its elec-
trical cable.  

 

Route cables/hoses such that they are 
protected from damage and do not pre-
sent a tripping hazard. 

 

Only open the unit housing or its at-
tendant components, when this is ex-
plicitly required in the operating instruc-
tions. 

 

Only carry out work on the unit that is 
described in this manual. If problems 
cannot be overcome, please contact an 
authorised customer service point or, 
when in doubt, the manufacturer. 

 

Only use original spare parts and acces-
sories for the unit. 

 

Never carry out technical modifications 
to the unit. 

 

Power connection cables cannot be re-
placed. If a cable is damaged, dispose 
of the respective unit or components. 

Summary of Contents for promax cleardrain 14000

Page 1: ...ProMax MudDrain 7000 11000 14000 ...

Page 2: ...2 ProMax MudDrain 7000 11000 14000 A POX0008 B POX0013 C D POX0010 POX0011 ...

Page 3: ... 3 E POX0009 ...

Page 4: ... Additional information A Reference to a figure e g Fig A Reference to another section PRODUCT DESCRIPTION Overview A ProMax Mud Drain 7000 11000 14000 1 Handle adjustable 2 Pump base 3 Float switch 4 Connection pressure side G1 5 Power connection cable 6 Stepped hose adapter Intended use ProMax MudDrain 7000 11000 14000 re ferred to in the following as unit may only be used as specified in the fo...

Page 5: ...e Only plug the unit into a correctly fitted socket Safe operation Dangerous electrical voltage Possible death or severe injury from electrocu tion Before reaching into the water al ways switch off and disconnect isolate all units located in the water with a volt age of 12 V AC or 30 V DC and se cure them from being switched on again Only operate the unit if no persons are in the water Never opera...

Page 6: ...s function ensure that the length of cable between the float switch and the cable clip measures at least 10 cm N O T E The minimum residual water height is only reached in manual mode Manual mode The pump remains permanently switched on if the float switch is set vertically and the cable points downward N O T E The pump can run dry in manual mode Switch off the pump when the minimum water level is...

Page 7: ...se this will impair the operat ing life of the unit accordingly N O T E Rinse the pump with clean water after use REMEDY OF FAULTS Malfunction Cause Remedy Pump does not start Power supply interrupted Check the fuse and electri cal plug connections Pump switches off after a short running period Overload protection has switched the pump off due to overheating Clean the intake and pressure hose Allo...

Page 8: ...and chlorine free household cleaning agent After cleaning thoroughly rinse all parts in clean water WEAR PARTS Wear parts are excluded from the war ranty The following components are wear parts and may only be replaced by the OASE Service Impeller STORAGE OVER WINTERING The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store ...

Page 9: ...tion pressure side G1 G1 G1 Minimum switch on height maximum switch off height mm 500 250 530 270 530 270 Maximum switch on height minimum switch off height mm 670 120 700 100 700 100 Flow rate max l h 7500 11500 14500 Head height max m 5 7 11 Immersion depth max m 7 7 7 Particle size max mm 30 30 30 Power connection cable Length m 10 10 10 Dimensions Length mm 193 193 193 Width mm 247 247 247 Hei...

Page 10: ...POX0039 ...