background image

 

11 

-  GB  - 

 

Changing the lens (G) 

 

 

 

Attention! Dangerous electrical voltage. 
Possible consequences:

 Death or severe injury. 

Protective measures:

 

  Prior to reaching into the water, disconnect the power supply to all units used in the water. 

  Disconnect the power plug prior to carrying out work on the unit. 

 

Each lamp is fitted with a 30° lens. The lens can be replaced by a 10° lens (part of the scope of delivery). 

How to proceed: 

  Hold the lamp at its foot (15). Do not hold at the end cap (16), as it would unscrew. 

  Hold the front cap (19) using a leather or textile cloth (to enhance the grip!) and unscrew counter-clockwise. 

  Slightly tap to remove the protection disk (18) and the lens (17) from the lamp. 

  Replace the lens, then reassemble the unit in the reverse order. 

 

Cleaning 

 

 

 

Attention! Dangerous electrical voltage. 
Possible consequences:

 Death or severe injury. 

Protective measures:

 

  Prior to reaching into the water, disconnect the power supply to all units used in the water. 

  Disconnect the power plug prior to carrying out work on the unit. 

 

If necessary, clean the unit with clear water using a soft brush. 

  Ensure that no moisture can enter the unit. 

 

Malfunctions 

Malfunction 

Cause 

Remedy 

Lamp does not light up 

Power supply interrupted 

Check power supply  

Light intensity decreases 

Lamp glass soiled 

Clean 

 

 

Repair 

Neither the power pack nor the LED spotlight can be repaired in the event of damage to the cables or the housing and 
have to be replaced. For your own safety, consult a qualified electrician or your specialist dealer if you have questions 
or encounter problems! 

 

Storage 

Clean the unit and check for damage. Store at a place inaccessible to children. 

 

Disposal 

 

 

 

Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided. 
Disable the unit beforehand by cutting off the cables. 

Summary of Contents for Lunaqua Maxi LED

Page 1: ...Lunaqua Maxi LED Set 1 Set 3 Solo...

Page 2: ...2...

Page 3: ...3...

Page 4: ...n die entsprechenden Ma nahmen nicht getroffen werden Gefahr von Personensch den durch eine allgemeine Gefahrenquelle Das Symbol weist auf eine unmittelbar drohende Gefahr hin die den Tod oder schwere...

Page 5: ...gung bereinstimmen Die Ger tedaten befinden sich auf dem Typenschild am Ger t oder auf der Verpackung oder in dieser Anleitung Das Ger t muss ber eine Fehlerstrom Schutzeinrichtung mit einem Bemessung...

Page 6: ...sen und darf nicht daf r verwendet werden Leuchte aufsetzen und festschrauben Darauf achten dass die Mutter 8 in der kleinen Bohrung und die Schraube 11 mit Schraubenkappe 12 in der gro en Bohrung der...

Page 7: ...zungen Schutzma nahmen Bevor Sie ins Wasser greifen Netzstecker aller im Wasser befindlichen Ger te ziehen Vor Arbeiten am Ger t Netzstecker am Ger t ziehen Gegen unbeabsichtigtes Wiedereinschalten si...

Page 8: ...ger which can lead to death or severe injuries if the appropriate meas ures are not taken Risk of injury to persons due to a general source of danger This symbol indicates an imminent danger which can...

Page 9: ...ified electrician The unit may only be connected when the electrical data of the unit and the power supply coincide The unit data is to be found on the unit type plate or on the packaging or in this m...

Page 10: ...be used for this purpose Place the light on the foot and screw tight Ensure that the nut 8 is in the small hole and the screw 11 with screw cap 12 is in the large hole of the screw connection 13 and...

Page 11: ...uences Death or severe injury Protective measures Prior to reaching into the water disconnect the power supply to all units used in the water Disconnect the power plug prior to carrying out work on th...

Page 12: ...espondantes ne sont pas prises Risque de dommages aux personnes d une source de danger g n rale Le symbole attire l attention sur un danger directement imminent pouvant entra ner la mort ou des blessu...

Page 13: ...t Les donn es de l appareil sont indiqu es sur la plaque signal tique de l appareil ou sur l emballage ou dans cette notice d emploi Veiller ce que l appareil soit absolument prot g par fusible par le...

Page 14: ...au plafond et il est d s lors interdit de l utiliser cet effet Placer l l ment d clairage et le visser fond Veiller ce que l crou 8 dans le petit per age et la vis 11 avec le capuchon 12 dans le grand...

Page 15: ...raves Mesures de protection Retirer la prise de secteur de tous les appareils se trouvant dans l eau avant de toucher l eau Retirer la prise de secteur de l appareil avant de proc der des travaux sur...

Page 16: ...e dood of zware verwondingen tot gevolg kan hebben als geen passende maatregelen worden getroffen Gevaar voor persoonlijke schade door een algemene gevarenbron Het symbool wijst op een onmiddellijk dr...

Page 17: ...aat is slechts toegestaan als de elektrische gegevens van het apparaat en de voeding overeenkomen De apparatuurgegevens bevinden zich op het typeplaatje op het apparaat of op de verpakking of in deze...

Page 18: ...niet worden gebruikt Lamp plaatsen en vastschroeven Let erop dat de moer 8 in de kleine boring en de schroef 11 met schroefkap 12 in de grote boring van de schroefverbinding zitten en de blokkeringsn...

Page 19: ...u in het water grijpt dient u eerst de stekkers van alle apparaten die zich in het water bevinden uit het stopcontact te trekken Voor werkzaamheden aan het apparaat de stekker uit het stopcontact tre...

Page 20: ...light M tt p transformator Kabell ngd f r transformator Kabell ngd f r spotlight Doppningsdjup Vikt Vattentemperatur FI Kohdevalon mitat Mittaukset muuntajalla Kaapelipituus muuntajalla Kaapelipituus...

Page 21: ...ing Spot SE Effekt M rksp nning f r transformator Utg ngssp nning fr n transformator M rksp nning f r spotlight FI Ottoteho Mitoitusj nnite muuntajalla L ht j nnite muuntajalla Mitoitusj nnite kohdeva...

Page 22: ...beskyttet Beskyttet mot vannsprut Minimumsavstand til gjenstanden som skal opplyses m v re 0 5 m Skift alltid ut glasskiver med sprekker SE Dammt t Vattent t till 3 m djup Dammskyddad Skyddad mot drop...

Page 23: ...transformator Ikke se direkte inn i lyskilden Beskytt mot direkte sollys Ikke kast i alminnelig husholdningsavfall NB Les bruksanvisningen SE Skyddsklass 3 S kerhetstransformator Titta inte direkt in...

Page 24: ...15188 09F...

Reviews: