Replacing the UVC lamp 

 

 

 

Attention!

 Dangerous electrical voltage. 

Possible consequences:

 Death or severe injury. 

Protective measures:

 Isolate the unit prior to reaching into the water and carrying out any work on the unit. 

Secure the unit from being switched on inadvertantly. 

 

 

 

Attention! Breakable glass. 
Possible consequences:

 Injury of your hands caused by cuts. 

Protective measures:

 Handle both quartz glass and UVC lamp with care. 

 

 

 

Note! 

  Condensate forms in the quartz glass tube. This condensate cannot be avoided, however, it does not impair 

function and safety. 

  The quartz glass tube can become scratched or blind over time. In this case, sufficient cleaning perform-

ance of the UVC lamp is no longer guaranteed. The quartz glass tube 

 

must be replaced. 

  The UVC lamp must be replaced after approx. 8000 operating hours. Only use UVC lamps the designation 

and rating of which match the information on the type plate. 

 
 

Figure (R, S, T, U, V) 
How to proceed: 

  Remove the UVC unit head (

Æ

Removing/inserting the UVC unit head). 

  Clean the quartz glass tube (R 19) externally using a moist cloth. 

  Undo the fastening screw (46) from the retaining ring (45), and unscrew the retaining ring. 

  Remove the quartz glass tube including the O ring (S 47). 

  Pull the UVC lamp (T 49) out of the lamp base. 

  Pull the transport securing elements (48 and 50) from the UVC lamp and push over the new UVC lamp. 

  Insert the new UVC lamp. 

  Place the quartz glass tube (U 19) over the UVC lamp (49) again. 

  Push the O ring (47) and the retaining ring (45) over the quartz glass tube. 

  Tighten the retaining ring by turning it up against the stop (51). 

  Tighten the fastening screw (46) for the retaining ring (V).  

  Reinsert the UVC unit head (

Æ

Removing/inserting the UVC unit head). 

  Switch on the pond pump. 

  Connect the power plug of the UVC unit. 

 

Decommissioning/Storage/Over-wintering 

  Empty/drain the container, hoses and connections as much as possible. 

  Clean thoroughly and check the unit for damage. 

  Remove, clean, and store the filter lid with the UVC unit and all filter elements in a dry and frost-free place. 

  Ensure that the storage place is inaccessible to children. 

  Secure the installation place of the buried container such that it does not pose any risk of accident for persons or 

animals. 

 

Disposal 

Support us in our endeavour to keep our environment intact, and adhere to the following disposal information! 

 

 

Use our return system for disposal. Always make electrical 
units unusable by cutting the cables!

 

Disposal with the household waste: 

UVC unit (electronics!) 

Packaging 

UVC lamp (mercury!) 

Worn foam filters, sealing rings 

 

Filter container 

 

Summary of Contents for FiltoClear 12000

Page 1: ...FiltoClear 12000 16000 20000 30000...

Page 2: ...2...

Page 3: ...3...

Page 4: ...4...

Page 5: ...5...

Page 6: ...6...

Page 7: ...7...

Page 8: ...8...

Page 9: ...y caused by a general source of danger This symbol indicates an imminent danger which can lead to death or severe injuries if the appropriate meas ures are not taken Important information for trouble...

Page 10: ...pacing to the UVC water housing 18 UVC water housing conveying water to the UVC unit 19 Quartz glass tube with UV C lamp Function description Figure A A filter pump only contained as a set in the scop...

Page 11: ...xperience he or she is capable of and authorised to judge and carry out the work commissioned to him her This also includes the recognition of possible hazards and the adherence to the pertinent regio...

Page 12: ...smantle at temperatures of 0 C and below Installation Figure A To be taken into consideration for planning Spacing between unit and water min 2 m safety spacing Do not expose the unit to direct sun ra...

Page 13: ...ecure with the hose clip Leave the last segment free for use as a window to control flow and soiling D Fitting the soiled water drain The soiled water resulting from cleaning the unit can be used for...

Page 14: ...hes on immediately the blue LED J 33 is lit Operation The unit is no longer biologically active at water temperatures below 10 C Take the unit out of operation at water temperatures below 8 C or at th...

Page 15: ...or severe injury Protective measures Switch off the mains voltage prior to carrying out work on the unit Opening the container Figure G How to proceed Push back safety latch 36 Press the closing hook...

Page 16: ...stress and normal ageing OASE recommend Replace old foam filters with new ones at the beginning of the new season Figure M N O Attention Dangerous electrical voltage Possible consequences Death or se...

Page 17: ...s tube including the O ring S 47 Pull the UVC lamp T 49 out of the lamp base Pull the transport securing elements 48 and 50 from the UVC lamp and push over the new UVC lamp Insert the new UVC lamp Pla...

Page 18: ...lampe maks damvolum Vanntemperatur SE Typ M tt Vikt vre m rksp nning Effekt Kabell ngd Anslutningar Filtervolym UVC lampa max dammvolym Vattentemperatur FI Tyyppi Mitat Paino mitoitusj nnite Tehonotto...

Page 19: ...208...

Page 20: ...209...

Page 21: ...210...

Reviews: