background image

 

19 

- GB - 

 

Unit configuration and function description 

Unit configuration 

 

Figure 
(B) 

Object 

 

Water return socket, for the return of filtered pond water 

 

Water inlet socket, for the inlet of soiled pond water 

Cleaning handle, the foam filters are compressed by pulling the handle up 

UVC unit head with temperature monitor, holder and control window for UV-C lamp. The UV-C lamp switches off automatically when 
overheated and on again once cooled down. 

Function switch to reverse the water flow. Turn counter-clockwise. 3 positions are available. 

 

I: Water filtering and radiation 

 

II: Foam cleaning („Easy-Clean Technology“) 

 

III: Flushing the UVC unit and the UVC water housing 

Bypass, optimises the UVC radiation effect at a high flow rate 

 

Soiled water drain socket, to drain the soiled water 

8 Filter 

lid 

Cover cap, with black flat sealing ring inserted 

10 

Clamping ring to hold filter lid and container together 

11 

Step, marking the maximum installation depth 

12 

Container, pressurised when the unit is in operation (max. 0.2 bar) 

13 

Fine foam filter for nitrification and denitrification  

14 

Coarse foam filter for nitrification 

15 

Fixing disk, holding foam filters on cleaning rods 

16 

Cleaning rod, connecting cleaning handle and filter disk 

17 

Meshed tube, maintaining the foam filter spacing to the UVC water housing 

18 

UVC water housing, conveying water to the UVC unit 

19 

Quartz glass tube with UV-C lamp 

 

Function description 

Figure (A) 
A filter pump (only contained as a set in the scope of delivery) presses the water into a pressure-tight container, where 
it passes several cleaning stages before returned into the pond. The soiled water resulting from cleaning the unit can 
be used to fertilise the garden. 
Figure B 
Cleaning stage "filtering": The water flows through the foam filters. Mechanical soiling is retained by the foam filters. 
Suspended matter and bio sludge settle on the container bottom. Usseful bacteria settle on the foam filters, cleaning 
the water biologically. Their effect starts at a water temperature of + 10 °C. 

 

Coarse foam filters (blue) 

Fine foam filters (red) 

high flow rate 

low flow rate 

Bacteria for nitrification 

Bacteria for nitrification and denitrification 

Ammonia -> nitrite -> nitrate reaction 

Nitrate -> nitrogen reaction 

 

Cleaning stage "radiation": The water is radiated with the ultra-violet light from a UV-C lamp. Green algae die, patho-
genic agents are killed. 
Bypass: A bypass ensures that only part of the returning water (approx. 25 %) is radiated. In this manner a sufficient 
radiation duration is obtained even at a high circulation rate. 
Filter starter: The unit only reaches its full biological cleaning effect after a few weeks. The formation of a bacterial 
community on the foam filters can be notably accelerated by adding filter starter bacteria. 

Summary of Contents for FiltoClear 12000

Page 1: ...FiltoClear 12000 16000 20000 30000...

Page 2: ...2...

Page 3: ...3...

Page 4: ...4...

Page 5: ...5...

Page 6: ...6...

Page 7: ...7...

Page 8: ...8...

Page 9: ...y caused by a general source of danger This symbol indicates an imminent danger which can lead to death or severe injuries if the appropriate meas ures are not taken Important information for trouble...

Page 10: ...pacing to the UVC water housing 18 UVC water housing conveying water to the UVC unit 19 Quartz glass tube with UV C lamp Function description Figure A A filter pump only contained as a set in the scop...

Page 11: ...xperience he or she is capable of and authorised to judge and carry out the work commissioned to him her This also includes the recognition of possible hazards and the adherence to the pertinent regio...

Page 12: ...smantle at temperatures of 0 C and below Installation Figure A To be taken into consideration for planning Spacing between unit and water min 2 m safety spacing Do not expose the unit to direct sun ra...

Page 13: ...ecure with the hose clip Leave the last segment free for use as a window to control flow and soiling D Fitting the soiled water drain The soiled water resulting from cleaning the unit can be used for...

Page 14: ...hes on immediately the blue LED J 33 is lit Operation The unit is no longer biologically active at water temperatures below 10 C Take the unit out of operation at water temperatures below 8 C or at th...

Page 15: ...or severe injury Protective measures Switch off the mains voltage prior to carrying out work on the unit Opening the container Figure G How to proceed Push back safety latch 36 Press the closing hook...

Page 16: ...stress and normal ageing OASE recommend Replace old foam filters with new ones at the beginning of the new season Figure M N O Attention Dangerous electrical voltage Possible consequences Death or se...

Page 17: ...s tube including the O ring S 47 Pull the UVC lamp T 49 out of the lamp base Pull the transport securing elements 48 and 50 from the UVC lamp and push over the new UVC lamp Insert the new UVC lamp Pla...

Page 18: ...lampe maks damvolum Vanntemperatur SE Typ M tt Vikt vre m rksp nning Effekt Kabell ngd Anslutningar Filtervolym UVC lampa max dammvolym Vattentemperatur FI Tyyppi Mitat Paino mitoitusj nnite Tehonotto...

Page 19: ...208...

Page 20: ...209...

Page 21: ...210...

Reviews: