22
Connecting the inlet
Use hoses that are suitable for a pressure of at least 1 bar.
Recommended combinations for using the hose sleeves:
Inlet
Outlet 1
Outlet 2
(opposite the inlet)
Required accessories
50 mm (2 in)
50 mm (2 in)
closed
–
38 mm (1½ in)
38 mm (1½ in)
closed
–
38 mm (1½ in)
38 mm (1½ in)
38 mm (1½ in)
For outlet 2 , a 38 mm (1½ in)
hose sleeve with a 38 mm (1½ in)
union nut
50 mm (2 in)
38 mm (1½ in)
38 mm (1½ in)
How to proceed:
C
1.
Push the inlet nozzle into the inlet.
–
The inlet nozzle is only necessary for a flow rate < 10000 l/h to ensure unimpaired rotation
of the cleaning rotor.
2.
Screw the hose connector with union nut and seal onto the inlet.
3.
Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the
hose clip.
Connecting the outlet
How to proceed:
D
1.
Screw the adapter with seal onto the outlet and hand tighten.
2.
Screw the stepped hose adapter with union nut and seal onto the adapter.
3.
Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the
hose clip.
4.
Screw the cover cap with flat seal onto the outlet.
–
The cover cap has to close the outlet opposite the inlet so that the main flow of water is
guided along the UVC lamps and is exposed to the UV radiation for as long as possible.
Connect the unit to the flow-through filter
•
Take the required distances into consideration. (
•
Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be in-
stalled below the water level. This allows the water supply to be shut off for maintenance
work.
Summary of Contents for Bitron Eco 120W
Page 2: ...A BTN0018 B BTN0008 C BTN0004 D BTN0013...
Page 3: ...3 E BTN0015 F BTN0017...
Page 4: ...4 G BTN0005 H BTN0016...
Page 201: ...BG 201 PDF www oase com manual 30 mA...
Page 202: ...202 UVC UVC...
Page 204: ...204 BTN0007 1 UVC UVC 2 UVC 3 UVC 9001 12000 6001 9000 3001 6000 1 3000 UVC UVC 4 C UVC...
Page 205: ...BG 205 pH 7 2 7 6 7 5 8 5 0 3 0 6 0 3 0 2 200 3 5 4 30 C 4 25 C A 2 B...
Page 209: ...BG 209 1 bar 3 4 10 C UVC 36 OFF 36...
Page 210: ...210 Eco 50 UVC 100 UVC 50 75 90 100 OF...
Page 212: ...212...
Page 213: ...UK 213 UK 8...
Page 215: ...UK 215 30...
Page 216: ...216...
Page 218: ...218 BTN0007 1 2 3 9001 12 000 6001 9000 3001 6000 1 3000 4 C...
Page 219: ...UK 219 pH 7 2 7 6 7 5 8 5 0 3 0 6 0 3 0 2 200 3 5 4 30 C 4 25 C A 2 B...
Page 223: ...UK 223 50 100 50 75 90 100 Off OF...
Page 225: ...UK 225 50 50 75 25 90 10 20 12 12 50 36 12 75 12 0 100...
Page 227: ...RU 227 PDF www oase com manual 30...
Page 228: ...228...
Page 230: ...230 BTN0007 1 2 3 9001 12 000 6001 9000 3001 6000 1 3000 4 C...
Page 231: ...RU 231 p 7 2 7 6 7 5 8 5 0 3 0 6 0 3 0 2 200 3 5 4 30 C 4 25 C A 2 B...
Page 235: ...RU 235 1 3 4 10 C 36 OFF 36...
Page 236: ...236 50 100 50 75 90 100 OF 100...
Page 239: ...CN 239 PDF www oase com manual 30 mA...
Page 240: ...240...
Page 246: ...246 1 bar 3 4 10 C UVC 36 OFF 36 Eco 50 UVC UVC 100 50 75 90 100 OFF...