Installation

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures:

•  Only operate the unit with the protection hood fitted.

•  Ensure that the unit is installed water-tight with a safety distance from the water of a minimum of 

6.6 ft (2 m).

Grounding instructions

This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of 

electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord 

having an appliance-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet 

that is installed and grounded in accordance with all local codes and ordinances.

Warning

Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check with a qualified 

electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not modify the 

plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician.

Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC).

2. 

  Cut the adapter as shown using a hacksaw; 

consult packaging for tubing size. This helps to avoid 

pressure loss. (BioPress 1600 / 2400 only)

3.

   Push the union nuts over the stepped hose adapters, 

push the tubing on the on the stepped hose adapter, 

and secure with the hose clips.

4.

   Insert the flat sealing ring or the O ring into 

the 

union nut for the black hose adapter and screw onto 

the pressure filter inlet.

!

1.

   

Place the pressure filter in a flood protected position 

at a distance from the pond edge of at least 6.6 ft (2 m) 

on firm and level ground. As an alternative, the filter 

can also be partly buried up to approx. 2 in (5 cm) 

below the closing clamps. 

○ The height difference between the filter lid and the 

free outlet point should be a maximmum of 6.6 ft (2 m). 

○ 

Ensure unrestricted access to the cover to be able to 

carry out work on the unit.

2.

3.

4.

1.

 

 

3.

4.

BioPress 1000

BioPress 1600 / 2400

Summary of Contents for BioPress UVC 1000

Page 1: ...BioPress UVC 1000 1600 2400 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...e with the purchase of this product BioPress UVC 1000 1600 2400 Prior to operating the unit please read the instructions of use carefully and fully familiarise yourself with the unit Ensure that all w...

Page 3: ...aken Important information for trouble free operation Intended use BioPress UVC 1000 1600 2400 referred to in the following as unit may only be used as specified in the following For operation with cl...

Page 4: ...the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified technician Install the unit so that it...

Page 5: ...unintentional switching on Attention Never operate the unit with a water pressure of more than 2 9 psi 0 2 bar Important Switch the pump on first then the UVC clarifying unit Do not operate the unit...

Page 6: ...or dirty water from the water outlet returns to the garden pond Carry out quick cleaning first Should this prove insufficient clean the entire unit A blocked filter could lead to leakages Never use c...

Page 7: ...g by undoing the nut from the pulling rod To remove the nut hold the pulling rod using combination pliers Note Do not pull the pulling rod out of the cover 5 Pull off the foam filters 6 Clean under ru...

Page 8: ...equences Injury to your hands caused by cuts Protective measures Handle the quartz glass and UVC lamp with care Note For safety reasons the UVC lamp can only be switched on when the unit head has been...

Page 9: ...nd replace the UVC lamp Assembly of the UVC clarifying unit 6 Insert the quartz glass including the O ring against the stop in the unit head Press the O ring into the gap between unit head and quartz...

Page 10: ...municipal authority Issue Cause Solution The unit performance is not satisfactory Unit has been in operation only for a short time The complete biological cleaning effect is only achieved after sever...