Maintenance and cleaning (cont.)

Full cleaning

1.

   Disconnect all hoses by twisting off the union nuts.

2.

   

Open the closing clamps of the filter container.

○ BioPress 1000: Hold the filter container at the hold-

down element and lift off cover including the foam 

filter package.

○ BioPress 1600/2400: Lift off cover including foam 

filter package.

3.

   

Lift off cover including foam filter package.

4.

   Place the cover upside down onto a soft, clean surface, 

so that the foam filters with the press ring face up. 

○ 

Remove the press ring by undoing the nut from the 

pulling rod.

○ 

To remove the nut, hold the pulling rod using 

combination pliers.

Note: Do not pull the pulling rod out of the cover.

5.

   Pull off the foam filters.

6.

   Clean under running water by vigorously compressing 

and releasing. 

○ 

Clean the container, cover with meshed tube and 

press ring under running water.

7.

   Push on foam filters so that the pulling rod rests in the 

recess of the foam filters.

8.

   Fit the pressing ring with the rod guidance pointing 

down, and screw the nut onto the pulling rod.

○ 

To tighten the nut, hold the pulling rod using 

combination pliers.

○ Ensure that the meshed tube fits completely in the 

ring diameter.

○ 

Remove the cover sealing ring from the container 

and check for damage; clean or replace, and place 

on the top container rim.

9.

   

Press on the cover including the foam filter package, 

allow the closing clamps to engage.

○ Perform a quick cleaning (Section: Quick cleaning).

BioPress 1000

BioPress 1600 / 2400

 

 

Summary of Contents for BioPress UVC 1000

Page 1: ...BioPress UVC 1000 1600 2400 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...e with the purchase of this product BioPress UVC 1000 1600 2400 Prior to operating the unit please read the instructions of use carefully and fully familiarise yourself with the unit Ensure that all w...

Page 3: ...aken Important information for trouble free operation Intended use BioPress UVC 1000 1600 2400 referred to in the following as unit may only be used as specified in the following For operation with cl...

Page 4: ...the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified technician Install the unit so that it...

Page 5: ...unintentional switching on Attention Never operate the unit with a water pressure of more than 2 9 psi 0 2 bar Important Switch the pump on first then the UVC clarifying unit Do not operate the unit...

Page 6: ...or dirty water from the water outlet returns to the garden pond Carry out quick cleaning first Should this prove insufficient clean the entire unit A blocked filter could lead to leakages Never use c...

Page 7: ...g by undoing the nut from the pulling rod To remove the nut hold the pulling rod using combination pliers Note Do not pull the pulling rod out of the cover 5 Pull off the foam filters 6 Clean under ru...

Page 8: ...equences Injury to your hands caused by cuts Protective measures Handle the quartz glass and UVC lamp with care Note For safety reasons the UVC lamp can only be switched on when the unit head has been...

Page 9: ...nd replace the UVC lamp Assembly of the UVC clarifying unit 6 Insert the quartz glass including the O ring against the stop in the unit head Press the O ring into the gap between unit head and quartz...

Page 10: ...municipal authority Issue Cause Solution The unit performance is not satisfactory Unit has been in operation only for a short time The complete biological cleaning effect is only achieved after sever...

Reviews: