Start-up
Attention! Dangerous electrical voltage
.
Possible consequences:
Death or serious injuries.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Attention!
Never operate the unit with a water pressure of more than 2.9 psi (0.2 bar)
!
Important:
●
Switch the pump on first, then the UVC clarifying unit.
●
Do not operate the unit without water flowing through.
●
The unit switches on automatically when power
connection is established.
1. Switching on:
Connect power plug to the socket.
○
The Light Indicator is lit.
Note:
○
After a new installation, the unit will reach its full
biological cleaning effect after a few weeks.
○
The full effect on bacteria is only reached as at a
water temperature of 50 °F (+ 10 °C).
○
In the event of overheating, the installed
temperature monitor switches the UVC lamp off
automatically, the lamp automatically switches on
again once cooled down.
○
Check all connections for leaks.
2. Switching off:
Disconnect the power plug.
1.
BioPress 1000
BioPress 1600 / 2400
1.