- EN -
26
BioMaster 250/350/600, BioMaster Thermo 250/350/600/850
Cleaning/replacing the foam filter of the pre-filter
Prerequisite
•
The pre-filter has been removed.
(→
How to proceed:
T
1.
Turn the casing until the locking hooks are pushed
in, then pull off the casing.
2.
Remove the pre-filter pipe and foam filters.
–
BioMaster 250: 4 foam filters.
–
BioMaster 350: 5 foam filters.
–
BioMaster 600: 6 foam filters
–
BioMaster 850: 7 foam filters
3.
Rinse the foam filters in warm water. If necessary,
replace the foam filters.
4.
Assemble the pre-filter in the reverse order.
–
Ensure that the locking hooks lock in place in the
casing.
Cleaning/replacing the filter media
U
Filter media on delivery:
a
Foam filter
30 ppi
b
Foam filter
20 ppi
c
Hel-X bio-elements, always place them contained
in the bag into the strainer casing
Prerequisite
•
The unit head is removed.
(→
How to proceed:
U
1.
Remove all filter baskets.
2.
Clean the filter baskets and container.
3.
Use water to flush the filter media from the aquar-
ium.
–
If necessary, replace the filter media. Rinse the
new filter media thoroughly with warm tap water
prior to its first use.
4.
Insert the parts in the container in the reverse or-
der.
–
Carefully fit the filter baskets in the bottom re-
cess in the container. Correctly position the pre-
filter.
–
Ensure that the filter cover is positioned on the
foam filter in the top filter basket.
5.
Reassemble the unit in the reverse order.
Cleaning/replacing the impeller unit
Prerequisite
•
The unit head is removed.
(→
How to proceed:
V
1.
Pull off the venting element.
2.
Turn the pump lid counter-clockwise (bayonet lock)
and remove.
3.
Remove the impeller unit and clean. If necessary, re-
place.
4.
Fit the impeller unit, replace the pump lid and lock
(turn clockwise).
–
Ensure that the two rubber bearings are correctly
seated.
5.
Reassemble the unit in the reverse order.
Cleaning the valve box of the pre-filter
The valve box only has to be cleaned if venting does
not function even though the foam filters of the pre-
filter have been cleaned.
Prerequisite
•
The pre-filter has been removed.
(→
How to proceed:
W
1.
Undo the fasteners and pull off the valve box.
–
If necessary, carefully lift the fasteners using a
screwdriver.
2.
Remove the valve seal and both valve flaps. Clean
all parts.
3.
Assemble the valve box in the reverse order.
–
Ensure that the fitted valve flaps can be easily
moved.
–
Note
: Ensure that the opening in the valve seal is
precisely aligned to the opening in the suction
chamber.
Summary of Contents for BioMaster 250
Page 1: ...BioMaster 250 350 600 850 BioMaster Thermo 250 350 600 850...
Page 3: ...3 C 2 1 D 3 2 1 BMR0021 BMR0022...
Page 5: ...5 I 1 2 3 4x J 2 5 4 4x 1 3 BMR0014 BMR0015 K 4 L 1 2 25 24 23 22 3 BMR0006 BMR0023...
Page 6: ...6 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 M FSt0015 N BMR0026...
Page 7: ...7 O BMR0005 P 1 2 4 3 BMR0007...
Page 9: ...9 U BMR0024...
Page 170: ...BG 170 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 BG 8 A A...
Page 174: ...BG 174 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 Q 1 R 1 2 3 S LOCK UNLOCK...
Page 175: ...BG 175 OASE PumpClean...
Page 177: ...BG 177 V 1 2 3 4 5 W 1 2 3 X 1 2 3 4 5...
Page 179: ...UK 179 UK 8 A...
Page 181: ...UK 181 C 1 2 D 1 2 3 E 1 UNLOCK 2 F 1 2 LOCK G 1 UNLOCK 2 H 1 2 I 1 2 3...
Page 183: ...UK 183 N MAX IN OUT O P 1 2 3 4 Q 1 R 1 2 3 S LOCK UNLOCK...
Page 184: ...UK 184 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 OASE Pump Clean...
Page 186: ...UK 186 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 W 1 2 3 X 1 2 3 4 5...
Page 188: ...RU 188 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 RU 8 A A...
Page 193: ...RU 193 OASE Pump Clean...
Page 195: ...RU 195 W 1 2 3 X 1 2 3 4 5...
Page 197: ...CN 197 CN 8 A A...
Page 201: ...CN 201 OASE PumpClean HeatUp 25 50 75 100 150 200 250 300 400...
Page 204: ...77553 02 20...