background image

-  English  -

3

2

Questions, problems, missing parts? 

Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email 

us at [email protected].  Or visit our website at www.oase-livingwater.com

-  English  -

REMINDER 

 

CALL 1-866-627-3435  

BEFORE RETURNING TO STORE.

Part

Description

QTY

A

Flow control

1

B

Cover

1

C

Foam filter

1

D

1/2˝ adapter

1

E

Pump housing

1

F

Cable lead to socket

1

Information about these operating instructions

Welcome to OASE Living Water. You made a great choice with the purchase of this product 

Aquarius Universal.

 Prior 

to operating the unit, please read the instructions of use carefully and fully familiarize yourself with the unit. 

Ensure that 

all work on and with this unit is only carried out in accordance with these instructions. Please strictly follow the enclosed 

instructions to ensure safe and correct handling of the product. Keep these instructions in a safe place. Please also hand 

over the instructions when passing the unit on to a new owner.

      WARNINGS AND CAUTIONS SYMBOLS

Symbols used in these instructions

The symbols used in this operating manual have the following meanings:
          Risk of injury to persons due to dangerous electrical voltage.

This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are 

not taken.

          Risk of personal injury caused by a general source of danger.

This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are 

not taken.

          Important information for trouble-free operation.

!

Intended use

Aquarius Universal, referred to in the following as “unit”, may only be used as specified in the following:
− For pumping clear water used for indoor and outdoor fountain pumps, table fountain pumps and statues. 

− Aquarius Universal 80: Only operate in closed rooms. 

•  Operation under observance of the technical data. 

The following restrictions apply to the unit:

−  Do not use in swimming ponds. 

−  Never use the unit to convey fluids other than water.

−  Never run the unit without water. 

−  Do not use for commercial or industrial purposes. 

 − Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances. 

 − Do not connect to the domestic water supply.

Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of 

pacemakers.

Use other than that intended

This unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance 

with these instructions or modification(s) to the unit will void the limited warranty.

A.

B.

!

C.

D

E.

D.

F.

E.

Part

Description

QTY

A

Flow control

1

B

Cover

1

C

Pump housing

1

D

Stepped barb adapter 
( 1/2˝, 3/4˝, 1˝)

2

E

Cable lead to socket

1

Aquarius Universal 80

Aquarius Universal 180 / 370

A.

B.

C.

Summary of Contents for AQUARIUS UNIVERSAL 80

Page 1: ...Aquarius Universal 80 180 370 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...juries if the appropriate measures are not taken Risk of personal injury caused by a general source of danger This symbol indicates an imminent danger which can lead to death or severe injuries if the...

Page 3: ...rizontally with its feet downward To prevent air from being taken in ensure that unit and supply hose are always below the water level 2 3 1 2 3 Start up Attention Dangerous electrical voltage Possibl...

Page 4: ...at de votre Aquarius Universal constitue un excellent choix Avant d utiliser la pompe lisez les instructions attentivement et familiarisez vous parfaitement avec l appareil Assurez vous que tout trava...

Page 5: ...our les personnes en raison d un danger d ordre g n ral Ce pictogramme indique un danger imminent pouvant entra ner la mort ou des blessures graves si les mesures appropri es ne sont pas prises Rensei...

Page 6: ...qu une baisse de performance est d tect e Nettoyez l unit avec de l eau chaude l aide d une brosse douce N utilisez jamais de produits de nettoyage agressifs ou de solutions chimiques Ceux ci pourraie...

Page 7: ...sin circulaci n de agua No emplee el equipo para fines industriales No emplee el equipo en combinaci n con productos qu micos alimentos y sustancias f cilmente inflamables o explosivas No conectar a...

Page 8: ...s en la entrada y el retorno Coloque el tubo 3 Coloque la unidad horizontalmente con los pies hacia abajo Para evitar que entre aire aseg rese de que la unidad y la manguera de suministro est n siempr...

Page 9: ...227 AC 120 V 60Hz 4 W 80 GPH 300 LPH 1 5 ft 0 45 m 3 3 ft 1 m 39 95 F 4 35 C 6 ft 2 m 0 62 lbs 0 3 kg 2 x 2 x 2 in 50 8 x 50 8 x 50 8 mm 180 37228 8 W 180 GPH 680 LPH 4 9 ft 1 5 m 16 ft 5 m 2 56 lbs 1...

Page 10: ...Pos Aquarius Universal 80 1 20331 Pos Aquarius Universal 180 370 1 23641 23641 2 20333 20354 3 26187 26187 4 26191 26191...

Page 11: ...OASE North America INC www oase livingwater com 19651 02 18...