8.0 Trouble shooting
Caution: Follow the safety instructions (section 4.0).
Pump does not turn on
Pump does not displace
water
Insufficient water dis-
placement
The pump turns off after
running for a short time
•
There is no power
•
Filter housing is blocked
•
Rotor is blocked
•
Filter housing is blocked
•
Excessive loss in the supply
lines
•
Water is very dirty
•
The water temperature is too
high
•
Check the electrical circuit
•
Clean filter housing (section 6.0)
•
Clean pump (section 6.2)
•
Clean filter housing (section 6.0)
•
Reduce hose lengths to the
minimum required, do not use
unnecessary connecting parts
•
Clean pump (section 6.0)
•
Insure that the water temperature
does not 35°C
Malfunction
Cause
Remedy
9.0 Parts subject to wear
Impeller
10.0 Technical data
Aquamax
3500
5500
10000
15000
Nominal voltage [V]
AC 230 V/50 Hz
Power consumption in watts [W]
53
75
110
250
Max displacement [l/min]
60
92
150
250
Max. displacement height [mdh]
1.6
2.5
3.4
5.0
Discharge nozzle connection
G 1 ½"
Suction nozzle connection
G 1 ½"
Filter surface [cm²]
730
Weight [kg]
4
4
4
4,3
Cable length [m]
10.0
10.0
10.0
10.0