11
- GB -
DMX-RDM
This unit supports the DMX protocol extension RDM. RDM (Remote Device Management) is a new, open and bi-
directional protocol standard for DMX-512 controlled units. The protocol allows to receive status information about a
unit or to change configurations on a unit. Prerequisite for this function being an RDM compatible controller. E.g. Oase
WECS 1024.
How does RDM work?
The permanently transmitted DMX data flow briefly pauses (several milli-seconds), and an RDM data package (mes-
sage) is sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an
answer (semi-duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several
subscribers from answering simultaneously.
RDM parameter overview:
General parameters
GET
CMD
SET
CMD
Description
COMMS_STATUS
*
*
Shows general status information of the bus interface
STATUS_MESSAGES *
STATUS_ID_DESCRIPTION *
Used to manage status messages
SUPPORTED_PARAMETERS
*
RDM parameter overview
PARAMETER_DESCRIPTION
*
Description of all parameters
DEVICE_INFO
*
Brief overview of the most important features
PRODUCT_DETAIL_ID_LIST *
Additional
feature
DEVICE_MODEL_DESCRIPTION * Type
designation
MANUFACTURER_LABEL *
Manufacturer
name
DEVICE_LABEL
* * Labelling
field
SOFTWARE_VERSION_LABEL
*
Version number of the firmware
DMX_PERSONALITY
*
*
Operating behaviour (currently the setting cannot be changed)
DMX_START_ADDRESS
*
*
Reading and setting the DMX start address
SENSOR_DEFINITION *
Sensor
information
SENSOR_VALUE
* * Sensor
value
Sensor 1 = „TempErrCount“, temperature error counter
Sensor 2 = „MotorFailureCount“ motor failure counter
Sensor 3 = „ActualSpeed“, current actual speed
Sensor 4 = „NominalSpeed“, current setpoint speed
Sensor 5 = „PWM“, current PWM value
Sensor 6 = „Temp“, current operating temperature
RECORD_SENSORS
*
Buffering the sensor value
IDENTIFY_DEVICE
*
*
0 = Normal operation,
1 = Pump will switch on and off again in short intervals. This function is helpful to
identify the unit in the field.
RESET_DEVICE
*
Executes a reset.
1 = Warm start / 255 = Cold start
Specific parameters
GET
CMD
SET
CMD
Description
Curve X1
*
Curve Y1
*
Support value 1 of the stored pump characteristic curve
Curve X2
*
Curve Y2
*
Support value 2 of the stored pump characteristic curve
Curve X3
*
Curve Y3
*
Support value 3 of the stored pump characteristic curve
Error monitoring
*
Only for service purposes
Runtime hours
*
Operating hour counter for the running period
Startup counter
*
Startup counter
Control mode
*
Only for service purposes
Config mode
*
Only for service purposes
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
−
Prior to reaching into the water, disconnect the power supply to all units used in the water.
−
Disconnect the power plug prior to carrying out work on the unit.
If necessary, clean the unit with clear water using a soft brush.
−
Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
−
In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.