![oaniso BCP Series Use And Installation Manual Download Page 23](http://html2.mh-extra.com/html/oaniso/bcp-series/bcp-series_use-and-installation-manual_3110250023.webp)
Operating status
EV charger
Emergency stop protection
CP signal abnormal
Poor grounding/Nature and live wire
reverse connection
Over-voltage
Protection
Under-voltage
protection
Over-current
protection
Temperature
protection
Leakage
protection
LED light
Yellow light on
Yellow & red LED flicker
alternately (interval 1s)
Red light on
Red light flashes (flashing once every
500MS and
then repeating after
waiting 2 seconds)
Red light flashes (2 flashes at 500MS
intervals, and then repeats after
waiting for 2 seconds)
Red light flashes (interval 500MS)
Red light flashes (interval 200MS)
Red light flashes (interval 500MS
flashes 3 times,wait 2 seconds
and repeat)
LED board is offline
The yellow light is on once and then
flashes 2 times
intermittently (after
the yellow light is on for 1second,
it flashes 2 times and 2 seconds at an
interval of 250MS)
DLB offline
Current abnormal
The yellow light is on once and the red
light is flashing once intermittently
(after the yellow light is on for 1 second,
the red light flashesonce at 250MS
intervals and repeats after 2 seconds.
The yellow light is on once and the red
light is flashing 2 times intermittently
(after the yellow light is on for 1 second,
the red light flashes 2 times and 2
seconds
at an interval of 250MS)
Operating status
Buzzer prompt description
Buzzer
Short buzzing one sound
Short buzzing two sounds
Long buzzing one sound
Status
Operating
Swipe to start
Swipe to quit
Swipe failure
Start charging
Stop charging
NONE
P-19