![oaniso BCP Series Use And Installation Manual Download Page 19](http://html2.mh-extra.com/html/oaniso/bcp-series/bcp-series_use-and-installation-manual_3110250019.webp)
Rotary Switch Position
0
1
2
3
4
5
6
7
Output Current
6A
8A
10A
12A
16A
20A
25A
32A
Installation instructions
Step-by-step installation instructions
(rear entry wiring)
Step
3
lnstall the EV Charger to the
mounting
plate.
Find the hole for cut out on the back
of EV charger.
Use the 4pcs M6*8 screws to fix the
EV charger to the mounting plate as
picture shows (Screws torque 1.5NM-
2.0NM).
Step
4
Wiring
Note: Consult with your local electrician
or refer to your local code for proper
wire sizing appropriate for the currents
in your EV Charger.
Note: lt is the installer's responsibility to
identify whether additional grounding is
required to ensure that local regulations
are met.Grounding must be installed at
the power sourceand not at the cable
entry to the EV Charger.
As the picture at left shows, use the
screwdriver loosing the screws on the
EV charger cover. Wire the cable to the
according terminal.
Left hole position
Right hole
position
Back of EV charger
perforating
as image
M6
*
8 bolts
cable through the hole
on the wall and
connect to the back
hole of EV
Wiring teminals
Three
-
phase
wiring diagram
Installation instructions
Do not connect the power cord before reading and fully understanding all the
concepts introduced in this section. If you are not sure whether the type of power
supply on the repair panel is available, please consult an electrician for assistance.
Be careful of electric shock! Before use, use a voltmeter to confirm that there is no
voltage on the power supply line or terminal to ensure that the power has been cut
off.
Warning
Set the operating current
Set the rotary switch for the appropriate current setting.Use a small flathead screwdriver
to adjust the rotary switch to the appropriate output current.
●
Warning
Power MUST remain OFF before setting or changing the DIP or rotary switches.Changing
these switches with the power ON will not be recognized by the system and is
dangerous due to the risk of electric shock.
1. Turn OFF power.
2. Use a non-conductive object (such as a plastic pen) to adjust the DlP switch settings:
P-15
P-16