background image

When moving the table, place one person at each corner of the table. Have each person firmly grasp the 

base at the bottom and lift the table. Be aware and use proper, safe procedures for moving a table of this 

size to prevent injury to yourself or the table. We strongly recommend that a flatbed dolly be used that can 

hold the entire table when moving the table long distances.

CAUTION

MOVING THE TABLE

Before moving the table, disconnect the power cord from the power outlet. The table 

weighs as much as 250 lbs. (113 kg.) Never lift the table by grasping the table top. 

You could damage the table and the electronics that run the tabletop. Four people 

are required to move the table safely. Do not use the table to transport a patient.

DIRECTIONS FOR USE

Grasp at 

base corner

at low height range

1/2” (13mm) Open

end Wrench

Leveler Foot

1.  Place the table in the location where 

you plan to use it.

2.  Rock the table to determine if it is 

level with the floor. If the table rocks 

back and forth at all, the foot that clears 

the floor when you rock the table will 

need 

adjustment.

3.  Adjust the Leveler Foot by first 

loosening the locking nut found just 

above the rubber Leveler Foot with the 

open-end wrench.

4.  Lower the adjustable rubber Leveler 

Foot until it meets the floor snugly. 

Tighten the locking nut against the  

wooden leg of the table with the open-

end wrench to fix the Leveler Foot in 

position.

5.  Rock the table again to be sure 

adjustments have stabilized the table. 

If necessary make any additional  

adjustments in the same way.

Tighten Locking Nut

Locking Nut

LEVELING THE TABLE

13

Summary of Contents for PerformaLift 1-Section Flat Top

Page 1: ...e Breast Comfort System 2 Section Lift Assist Backrest Top Shown with optional Adjustable Breast Comfort System Series USER MANUAL www OAKWORKS com 717 235 6807 made in the USA with US imported parts...

Page 2: ...d within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like docume...

Page 3: ...Assist Backrest Flat Top Tables Only 11 Adjustable Breast Comfort ABC Systems Only 12 Moving the Table 13 Leveling the Table 13 Adjustable Breast Comfort ABC System 14 QuickLock Face Rest 15 Integrate...

Page 4: ...ease and comfort The fully electric Performalift Series is especially effective when professional protocols require specific positioning for the client or patient While the client receives comfortabl...

Page 5: ...ing administered Do not lift table by the table top This can damage the table When lowering the table make sure there is nothing underneath the table top that can impede motion like stools cabinets ac...

Page 6: ...owered motions Hand Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg patient and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 4 section 73...

Page 7: ...ns Hand Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg patient and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 2 section 73 185 cm Padd...

Page 8: ...ered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg patient and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 2 section 73 185 cm Padding 4 10 cm or 6 15 cm...

Page 9: ...is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all l...

Page 10: ...amage can occur to the table The Oakworks Performalift TM Electric Salon Tables offer trendelenburg height backrest and footrest positioning with electronic ease Operate the foot control as shown belo...

Page 11: ...cur to the table The Oakworks Performalift TM Lift Assist Backrest and Flat Top tables offer trendelenburg and height positioning with electronic ease Operate the foot control as shown below to raise...

Page 12: ...our client The Oakworks Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable position for t...

Page 13: ...c ease Operate the hand control as shown below to raise or lower the trendelen burg height backrest or footrest functions of the table MEM1 MEM2 Use any of the top 8 buttons to orient the table in a f...

Page 14: ...SE MEM1 MEM2 CAUTION For Lift Assist Backrest Tables Do not sit on backrest section The hood area under the backrest top is not designed for storage DO NOT use this area for holding anything Damage ca...

Page 15: ...lient The Oakworks Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable position for their...

Page 16: ...ot use the table to transport a patient DIRECTIONS FOR USE Grasp at base corner at low height range 1 2 13mm Open end Wrench Leveler Foot 1 Place the table in the location where you plan to use it 2 R...

Page 17: ...a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensure comfort support Once a client s preferences are known the cushion can b...

Page 18: ...the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under table cabinet until needed DIRECTIONS FOR USE QuickLockTM FACE REST...

Page 19: ...it once try plugging the table into another outlet Possible causes Two three blinking lights on the control switch indicates that the heating element connector s are not plugged in properly and or da...

Page 20: ...section All casters should be locked during use with a patient LOCKING CASTERS USE LOCKING THE CASTERS 1 Place your foot on the end of the casters locking tab 2 Press firmly downward until you hear a...

Page 21: ...MEM1 MEM2 MEM1 MEM2 1 Locate the Control Box and detach the strain relief by removing the screw holding it in place with a 2 5mm Allen wrench 2 Unplug the foot control from the 3rd control port in the...

Page 22: ...for 10 seconds 3 When no clicking noise is heard from the Control Box during this process the zero limits have been reached 4 Test table to ensure all functions are working properly Note If a non lev...

Page 23: ...OAKWORKS recommends a prepackaged wipe for cleaners disinfectants to ensure best distribution of disinfectant for the required kill time without leaving excess residue and or overexposing components t...

Page 24: ...wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check fo...

Page 25: ...rs are located on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 PMXA4EF1T411USXXXX Ser PAD123456 06 03 2020 Order 785461 Performalift...

Page 26: ...C 10 amp 50 60 Hz 100 VAC 15 amp 50 60 Hz Current Draw 5 0 amps 2 5 amps 5 0 amps Voltage Output to Actua tors 24 VDC 24 VDC 24 VDC Electric Shock Protection Class 1 Equipment Class 1 Equipment Class...

Page 27: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 24...

Page 28: ...7349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com USER MANUAL 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 Original Instructions Manual Part Number SPA RA PM 150 Revision l...

Reviews: