INSTRUCTION SHEET NO.
IS:2025WH
A0203 Page 1 of 1
INSTALLATION OF LYTECASTER
®
REFLECTOR TRIM IN THE 2000LV/2004ICV SERIES
FRAME-IN KITS WITH ROTO CLIPS
NOTE:
Installation and lamping procedures for the square and round
styles are the same as follows:
1. Frame-In (Fig. A)
See
Frame-In Kit
Instruction Sheet for installation procedure.
For use with 2000LV/2004ICV series Frame-In Kits only.
2. Rotate Roto Clips (Fig. B)
As shown in Fig. E.
3. Prepare Socket Cup
Remove the
Lamp Adjustment Mechanism
from the Socket
Cup by bending the the Tabs away (3 places), (see Fig. F & G).
4. Snap-On (Fig. C)
Insert Socket Cup into
Housing
. Make sure
Springs
of
Socket
Cup
snap into
Slots of Housing
Fig. C.
5. Push-in (Fig. D)
Push
Housing Trim
straight up until it is tight against ceiling.
6. Lamping (Fig. H and I)
Make sure that power is OFF when lamping or relamping.
Remove
Swivel Trim
from
Housing
by pulling straight down
(Fig. H). Place
Glass Lamp Guard
between
Lamp Spring
.
Place Lamp between
Lamp Spring
until face of Lamp sits firmly
onto
Glass Lamp Guard
(Fig. I). Attach Socket to Lamp. Insert
Swivel Trim
with Lamp and
Glass Lamp Guard
back into
Housing
. (If TAL type lamp is used, do not use glass lamp
guard.)
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local
or Federal code specifications. To assure full compliance with local codes and regulations, check with your
local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before
proceeding.
Retain these instructions for maintenance reference.
®
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
CAUTION:
• Lamp manufacturers require the Glass Lamp Guard
be in place before energizing lamp (with the
exception of TAL lamps), and that great care must
be taken to insure lamp is fully cooled before
relamping.
• Use only reflector trims provided by Lightolier Inc.
Use of other manufacturers’ reflector trims voids
the Underwriters Laboratories listing and could
constitute a fire hazard.
NOTES:
• Low voltage fixtures should be dimmed only with
special dimmers intended specifically for that pur-
pose. Use Lightolier Lytemode
®
, Scenist
®
,
Crescendo VA
®
, Neptune VA
®
, Precision VA
®
,
Easyset VA
®
, Sunrise VA
®
, Radiant VA
®
, or equiva-
lent products by others; or variable autotransform-
ers or electronic dimmers intended for use with
low voltage fixtures.
FIG. F
FIG. I
FIG. H
FIG. G
FIG. E