Though the arm rests adjust automatically to remain parallel to the 

floor in any position, there will still be times when you will need to 

move an arm rest out of the way or remove them altogether. We  

recommend that you raise the arm rest out of the way to allow a client to 

get on or off the table. They are designed to be strong and will take a 

reasonable amount of weight but they are not designed to be used to 

sustain a person’s weight when getting on or off the table. 

To Adjust the Arm Rest:

Before asking a client to mount or dismount from the table we recommend 

that you move the arm rest out of the way. The arm rests are easy to move 

and manually adjust. First position the tabletop with the backrest in 

the upright position and all other section flat. Take hold of the arm 

rest firmly and raise the arm rest up and out of the way with a steady 

swing until the arm rest is in the highest upright position (see images 

below). Hold it in place until your client has mounted (or dismounted)

and then actively move it back into the resting position where it will 

proceed to move automatically with the table top.

The arm rest is now set and will adjust automatically as you position the cli-

ent for whatever procedure is needed.

There will be times when removal of the arm rests will be needed. This 

feature is  helpful when doing massage or helping someone get on or 
off the 

Antigua

. This can be done easily and storage is conveniently 

located in the under-table cabinet. They are then at hand when you are 

ready to re-install.

To Remove the Arm Rest:

The arm rest frame has a notched connection to the interior of the the 

table top which allows it to move automatically when the table top 

changes position. (cont.)

DIRECTIONS FOR USE

SIDE ARMRESTS:

 

Be sure to read all 

 

 

cautions, warnings    

 

and instructions given   

in the manual to  prevent 
injury to both operator  
and client.

  • Side Arm Rests  

   

Adjusting the Side Arm Rest

Do not place excess 
weight on the Side Arm 
Rests. Do not use them in 
assisting the client on and 
off the 

Antigua

.

Either Arm Rest can be 
repositioned to allow a 
client to get on and off 
the  

Antigua

  

easily. 

When making adjustments 
the arm rests make certain 
that the client’s arms are 
away from the working 
mechanism.

Do not sit on the Arm Rests. 

IMPORTANT

10

Summary of Contents for antigua ATBR

Page 1: ...igua AVAILABLE WITH ROUND CORNER FLAT TOP BACKREST TOP ELECTRIC FLEX TOP SHOWN HERE Antigua Colonial AVAILABLE WITH ROUND CORNER FLAT TOP BACKREST TOP ELECTRIC FLEX TOP SHOWN HERE STANDARD WOOD DOOR S...

Page 2: ...bject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc assumes no responsibility for any errors that may appear in this document nor does it make expre...

Page 3: ...trol pg 5 Hand Control pg 6 Under Table Cabinet pg 7 Side Arm Rests pg 10 QuickLock Face Rest pg 12 Accessory Option Table Extender pg 14 Moving the Antigua pg 14 Section IV Troubleshooting If Table W...

Page 4: ...d in documentation on this product indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed on page 18 This symbol when used in documen...

Page 5: ...ower cord from the power outlet Do not operate the table in standing water Before moving the table disconnect the power cord from the power outlet and secure the electrical cord hand control and foot...

Page 6: ...ot designed to hold the weight of the base and you could damage the table When operating the Antigua controls and making any and all adjust ments to the table move hands and feet away from the working...

Page 7: ...terior power source by removing the plug from the outlet When moving the table Turn the accessory controls to the off position disconnect the table from the exterior power source by removing the table...

Page 8: ...es provided by an electronically adjustable flextop The variety of height and reclining positions align the Antigua top so your client s body is at the optimum level for any number of treatments It fe...

Page 9: ...ly designed access top allows the seated practitioner total ergonomic access to the client s head region reducing strain and fatigue Four maintenance free hydraulic cylinders are powered by a whisper...

Page 10: ...Specifications Chart measurements are determined from floor to top of seat pad using standard padding these measurements can be affected by natural material variations in padding published weight may...

Page 11: ...d wrench or an adjust able wrench Adjust each leg individually in turn by adjusting the height of each leveler foot until the unit rests level and steady This adjust ment will not effect the function...

Page 12: ...warnings as given in the manual Antigua When operating the Antigua controls be sure to observe all cautions and warnings given in the manual to prevent injury to both operator and client When operatin...

Page 13: ...vide the most in comfort and ergonomics while staying parallel to the floor no matter what the position Hand Control DIRECTIONS FOR USE Back Rest Control activates backrest down to level position Chil...

Page 14: ...ything Damage can occur to the table especially when commands that are accessed by the hand control are activated Placing anything on this area will prohibit movement of the backrest and can cause dam...

Page 15: ...ening Place the screws and the panel in storage in case of future need to reinstall the panel To re install the panel unplug and remove any appliances from the cabinet angle the panel into the opening...

Page 16: ...ening to allow the cord of the appliance to pass through the cabinet and access the interior outlet thus giving you complete power without the safety hazard and distraction of loose cords in the worki...

Page 17: ...ted and then actively move it back into the resting position where it will proceed to move automatically with the table top The arm rest is now set and will adjust automatically as you position the cl...

Page 18: ...notch slip into place Push it in securely and allow the arm rest to rest in the parallel position This resets the arm rest in the proper position for the automatic adjustment feature to be activated...

Page 19: ...locks into that position The Antigua has outlets at the head of the table for a variety of uses and outlets at the other end that work as well for additional procedures Attaching the QuickLock Face R...

Page 20: ...her or spread them apart to achieve the most comfortable support for any size face To avoid your client s chin from hitting the spacebar make sure the pad is narrow enough to support their whole face...

Page 21: ...h your legs beneath you and not with your back Be aware and use proper safe procedures for moving a table of this size to prevent injury to yourself or the table We strongly recommend that a flatbed d...

Page 22: ...Service at 800 558 8850 to arrange replacement TROUBLESHOOTING The table weighs as much as 200 lbs DO NOT lift or move the unit without using proper safety procedures or equipment DO NOT turn the Anti...

Page 23: ...olstery fabric involves more than just protecting it from general abrasions cuts and punctures We offer most of the products mentioned above in our therapeutic equipment catalog Therapeutic equipment...

Page 24: ...ER LEAD PLUGS OAKWORKS Part Voltage ACE Power Cord Plug 7791 120v 60 Hz 3 prong grounded North America 7791 03 220v 50 Hz Continental Plug Europe Italy 7791 04 220v 50 Hz Swiss plug Switzerland 7791 0...

Page 25: ...sions Opening Dimensions Storage Area 1 Head End Opening Dimensions Storage Area 2 Foot End 20 5 H x 24 5 W x 50 5 L 11 5 H x 20 W x 48 L 12 H X 20 4 L 12 H x19 9 L Cabinet Dimensions 52 1cm L x 62 2c...

Page 26: ...der QuickLock Face Rest 2 parts 0218 Platform 1 2410 xx Crescent Face Rest Pad 1 7811 xx Side Arm Rest Cushion Right 1 7812 xx Side Arm Rest Cushion Left 1 1732 xx Side Arm Rest Right assembly include...

Page 27: ...ll liability by OAKWORKS for the product or damages caused by its use The buyer and its customers shall be responsible for proper set up and use of the products as well as any supervision required for...

Page 28: ...KWORKS Inc 923 East Wellspring Road New Freedom PA 17349 Toll Free USA only 800 916 4613 Phone 717 235 6807 FAX 717 235 6798 www oakworks com Manual Part MMMNST0011 rev 51510 Edition 2 English January...

Reviews: