background image

6

All tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated 

for the table. (See Grounding below)
Arrange the power cord and control cords so that they will not create a tripping hazard and where the  

controls are located to your liking and are conveniently accessible.
Be sure access to plug is not blocked for disconnecting the table from power.

This product must be grounded. If it should malfunction or break down, grounding provides a path of least 

resistance for electrical current to reduce the risk of electric shock. This product is equipped with a cord 

having an equipment-grounding conductor and a grounding pin. The pin must be plugged into an  

appropriate outlet that is properly installed and grounded in accordance with all local codes and   

ordinances. See U.S. sample below.

Correct Implementation

Incorrect Implementation

Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only.

DANGER

INSTALLATION

GROUNDING

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check 

with a qualified electrician or service person if you are in doubt as to whether the product is properly 

grounded. Do not modify the plug provided with the product - if it will not fit the outlet; have a proper outlet 

installed by a qualified electrician.

Grounding Methods

Summary of Contents for PerformaLift Series

Page 1: ...tional Adjustable Breast Comfort System 2 Section Lift Assist Backrest Top Shown with optional Adjustable Breast Comfort System USER MANUAL www OAKWORKS com 717 235 6807 made in the with US imported 1...

Page 2: ...d within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like docume...

Page 3: ...Comfort ABC Systems Only 12 Moving the Table 13 Leveling the Table 13 Lift Assist Backrest Adjustment 14 Locking Casters Use Option 14 Removing Top Pad 15 Adjustable Breast Comfort ABC System Option...

Page 4: ...nal protocols require specific positioning for the client While the client receives comfort able relaxing support the comfort level of the therapeutic professional is enhanced by superior ergonom ics...

Page 5: ...administered Do not lift table by the table top This can damage the table When lowering the table make sure there is nothing underneath the table top that can impede motion like stools cabinets acces...

Page 6: ...ol All powered motions Hand Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 18...

Page 7: ...ll powered motions Hand Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm...

Page 8: ...nd Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6...

Page 9: ...is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all l...

Page 10: ...Damage can occur to the table The OAKWORKS PerformaLift Electric Salon Tables offer trendelenburg height backrest and footrest positioning with electronic ease Operate the foot control as shown below...

Page 11: ...ccur to the table The OAKWORKS PerformaLift Lift Assist Backrest and Flat Top tables offer trendelenburg and height positioning with electronic ease Operate the foot control as shown below to raise or...

Page 12: ...our client The OAKWORKS Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable position for t...

Page 13: ...ease Operate the hand control as shown below to raise or lower the trendelen burg height backrest or footrest functions of the table MEM1 MEM2 Use any of the top 8 buttons to orient the table in a fav...

Page 14: ...USE MEM1 MEM2 CAUTION For Lift Assist Backrest Tables Do not sit on backrest section The hood area under the backrest top is not designed for storage DO NOT use this area for holding anything Damage c...

Page 15: ...lient The OAKWORKS Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable position for their...

Page 16: ...ot use the table to transport a client DIRECTIONS FOR USE Grasp at base corner At low height range 1 2 13mm Open end Wrench Leveler Foot 1 Place the table in the location where you plan to use it 2 Ro...

Page 17: ...tion All casters should be locked during use with a client LOCKING CASTERS USE OPTION LOCKING THE CASTERS 1 Place your foot on the end of the casters locking tab 2 Press firmly downward until you hear...

Page 18: ...crews If the thumbs screws are on too tight a 5 32 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled...

Page 19: ...Sometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydeterm...

Page 20: ...standard 120V or 230V wall outlet Ensure heating element connectors 2 are properly connected to control box Check light indicator on front of the unit to ensure power is supplied If not illuminated af...

Page 21: ...ce To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under table cabinet until needed DIRECTIONS FOR USE QuickLock...

Page 22: ...rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The...

Page 23: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Page 24: ...1 MEM2 MEM1 MEM2 1 Locate the Control Box and detach the strain relief by removing the screw holding it in place with a 2 5mm Allen wrench 2 Unplug the foot control from the 3rd control port in the TC...

Page 25: ...for 10 seconds 3 When no clicking noise is heard from the Control Box during this process the zero limits have been reached 4 Test table to ensure all functions are working properly Note If a non lev...

Page 26: ...rocedure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts...

Page 27: ...control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand control R...

Page 28: ...rs are located on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 PMXA4EF1T411USXXXX Ser PAD123456 06 03 2020 Order 785461 PerformaLift...

Page 29: ...AC 10 amp 50 60 Hz 100 VAC 15 amp 50 60 Hz Current Draw 5 0 amps 2 5 amps 5 0 amps Voltage Output to Actuators 24 VDC 24 VDC 24 VDC Electric Shock Protection Class 1 Equipment Class 1 Equipment Class...

Page 30: ...27 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 31: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 28...

Page 32: ...6807 FAX 717 235 6798 www oakworks com USER MANUAL 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 Original Instructions Manual Part Number SPA RA PM 150 Revision level 3 Revision Dat...

Reviews: