Pressing and holding UP and DOWN arrow keys will increase or decrease text entries without 
an acceleration factor. The LEFT arrow button allows you move backwards through the GEN-
ERAL SETUP MENU (GSM) and ADVANCED SETUP MENU (ASM). While in the ASM, you 
can move backwards to the first ASM screen, but cannot back into the GSM. To exit to the 
main screen from either menu, press and hold the MENU button.  

 

HEAT, COOL, AND TUNE 

When any of these modes are active they will have a block 
indicator on the display showing they are active. Example: 
When the control is in the heat mode and it is applying pow-
er to the heater output there will be an indicator block on the 
display to show the heater output is active. 

 

 

 

 

 

 

 

 

BACK OF CONTROL SHOWN WITH 230 VOLT OUTPUT RECEPTACLE 

 Model 89800-01 & 89800-02 

 

1.  IEC power cord connection 

(see page 23 for additional cords)

 

2.  Fuse 

3.  Heater/Cooler output  (IEC 60320 on 230 volt, 5-15R on 115 volt) 

see page 24, 25 for op-

tional country cord adapters.

 

4.  Control Power Switch  

5.  Grid Support Bracket 

6.  Thermocouple, Type: J, K, N, R, S, T, B, and E 

 
 
How to Setup models: 89800-01 & 89800-02 

• 

Install control in safe operating area. 

• 

Plug Heater/Cooler into the output connector, located on the back of the control. 

• 

Connect input sensor into the proper connection input on control and place the sensor in 
the process. 

• 

Plug proper AC cord into the IEC connector (depends on country), located on back of the 
control. 

  

5-15R , 

115 VOLT  

Summary of Contents for TEMP 9000

Page 1: ...Oakton TEMP 9000 Advanced Thermocouple Controller Models 89800 01 89800 02 Oakton Instruments 625 E Bunker Ct Vernon Hills IL 60061 USA 1 888 4OAKTON 1 888 462 5866 info 4oakton com...

Page 2: ...teway 10 Loop Break Stop 11 Control Action 12 Set up Flow Chart 15 17 Main Screen information 15 General Setup Flow Chart222222222222222222222 16 Advanced Setup Flow Chart2222222222222222 2222 17 Spec...

Page 3: ...mage Replace all fuses with the cor rect fuse replacement Reference page 18 for Model 89800 01 and page 19 for Model 89800 02 WARNING Specifications for the power cord See page 18 for Model 89800 01 a...

Page 4: ...ser Sensor input types Thermocouple J K N R S T B and E The control automatically sets the PID parameters through a learning sequence in the tune mode PID parameters include proportional band reset in...

Page 5: ...llow you to cycle through user configurable control Set Points The Set Point selected will be underlined Set Points may be changed by using the UP and DOWN arrow keys MENU Button The MENU button provi...

Page 6: ...r output there will be an indicator block on the display to show the heater output is active BACK OF CONTROL SHOWN WITH 230 VOLT OUTPUT RECEPTACLE Model 89800 01 89800 02 1 IEC power cord connection s...

Page 7: ...erify that the Auto Tune feature is enabled in the menu settings From the System Status screen set the Set Point temperature Press the Tune button and the indicator showing Tune will have be illuminat...

Page 8: ...Selections Range Type J 190 C to 1000 C 310 F to 1832 F Range Type K 200 C to 1372 C 328 F to 2502 F Range Type N 200 C to 1300 C 328 F to 2372 F Range Type R 0 C to 1768 C 32 F to 3214 F Range Type S...

Page 9: ...mal op erating conditions Alarm Mode Default mode is Process High Use arrow keys to change alarm mode setting Available selections Process High Process Low and Process High Low Process High The alarm...

Page 10: ...arrow keys to change value ON or OFF Turns the audible alarm on or off Advanced Menu Gateway Press the menu key to advance into the advanced setup Press the DOWN key to exit to the system status scree...

Page 11: ...djust the value The use of another temperature device is required to figure correct offset needed Adjusting this value is offsetting the sensor input signal Over Temperature Stop Use UP DOWN arrow key...

Page 12: ...Mode On Off Control Use the UP DOWN arrow keys to adjust value The ON OFF hysteresis value tells the control how much above temperature SetPoint and below temperature SetPoint that the control will a...

Page 13: ...Setup Use the UP DOWN arrow keys to adjust value This is manual adjustment for the Derivative Rate of PID Only users with advance knowledge of PID controller operations should attempt the manual setup...

Page 14: ...output turned OFF if the time expires Power Failure Control Default value is RESUME Use arrow keys to change value Options STOP If control losses AC power during operation process will be stopped when...

Page 15: ...15...

Page 16: ...16...

Page 17: ...i br at i on Set up ENTER Ar e you sur e you want t o r eset t o DEFAULT poi nt s NO Ar e you sur e you want t o save t hese poi nt s NO Cal i br at i on Poi nt X Set Poi nt XXX Read Tem p XXX Segm en...

Page 18: ...25o C 2000m 2 Normally only non conductivity pollution occurs Local Level Connect to branch circuit and not directly to a main circuit such as a fuse panel Storage 0o C to 60o C Relative Humidity 5 to...

Page 19: ...5o C 2000m 2 Normally only non conductivity pollution occurs Local Level Connect to branch circuit and not directly to a main circuit such as a fuse panel Storage 0o C to 60o C Relative Humidity 5 to...

Page 20: ...310 F to 1832 F Range Type K 200 C to 1372 C 328 F to 2502 F Range Type N 200 C to 1300 C 328 F to 2372 F Range Type R 0 C to 1768 C 32 F to 3214 F Range Type S 0 C to 1768 C 32 F to 3214 F Range Type...

Page 21: ...21 UL File E207546 Vol 1 CE Approval...

Page 22: ...shall be the procurement of authorization from Oakton Instruments assigning a Return Goods Number to the product or part requiring service Parts and accessories manufactured by others are warranted on...

Page 23: ...23 Input power cord options for various countries...

Page 24: ...24 Country Cord Adaptors Europe Part 89800 19 Denmark Part 89800 21 England Part 89800 22 India Part 89800 23 Australia Part 89800 24...

Page 25: ...25 Country Cord Adaptors Switzerland Part 89800 26 Italy Part 89800 27 Israel Part 89800 28 USA Part 89800 29...

Reviews: