13
•
Use the UP & DOWN arrow keys to adjust value.
•
This is manual adjustment for the proportional band of PID. Only users with advance
knowledge of PID controller operations should attempt the manual setup.
Integral Time Setup
•
Use the UP & DOWN arrow keys to adjust value.
•
This is manual adjustment for the Integral Time of PID. Only users with advance knowledge of
PID controller operations should attempt the manual setup.
Derivative Rate Setup
•
Use the UP & DOWN arrow keys to adjust value.
•
This is manual adjustment for the Derivative Rate of PID. Only users with advance knowledge
of PID controller operations should attempt the manual setup.
ON / OFF Hysteresis
•
Use the UP & DOWN arrow keys to adjust value.
•
Cycle time is the rate that the output cycles on and off. The recommended time is 1 second.
•
If a mechanical relay is being used off the output it is recommended that the time be increased
to more than 1 second. Mechanical relays are slower than solid state relays and require more
time to operate correctly. Damage to the relay and control can occur if not set correctly.