INSPECTION AND INSTALLATION
Remove the unit from shipping carton
and SAVE all
protective packing materials.
Remove the White Ceramic Purification plate from its package. The ceramic plate is not installed in the air purifier by the
factory to prevent breakage during shipment. Verify that the White Ceramic Purification plate is intact and unbroken.
Remove filters (4) from rear of unit:
1. The pre-filter is removed by unscrewing the 4 thumb-screws on the back of the purifier.
2. The white HEPA filter is removed by pulling on the attached ribbon-tab at the top of the filter.
3. The black Activated Carbon filter is removed by pulling on the attached ribbon-tab at the top.
4. The Photo-Catalytic Filter is removed by pulling on the attached ribbon-tab at the top.
4. Check to make sure that the UV cartridges (bulbs) are not broken.
5. Now that all of the filters are removed, install the white Ceramic Purification plate [also referred to as O
3
Activated
Oxygen plate] into the purifier.
a) Make sure the plate is installed with the arrows pointing towards the inside of the unit.
b) Grasp the end of the ceramic plate and (following the photographs below) and slide the plate vertically into card
slot.
6. Reinstall the 3 inner filters in the following order:
FIRST
, with the ribbon to the outside, place the Photo-Catalytic Filter in the unit so that the safety tab can no longer
be seen.
CAUTION: When properly installed, the Photo-Catalytic Filter will push the safety tab towards the center
of the unit and will no longer be visible. See photos BELOW for proper installation.
***THE PURIFIER WILL NOT TURN-ON IF THIS FILTER IS NOT INSTALLED PROPERLY.
SECOND
, insert the black Activated Carbon filter. Make sure the ribbon-tab is on the outside
THIRD,
insert the HEPA filter in next. Make sure the ribbon-tab is on the outside.
LASTLY
, replace the Pre-Filter and install the 4 thumb screws to secure.
7. Determine a location for your unit(s). Allow a minimum of six inches between the back of the unit and the wall to allow
proper air flow. Elevated placement is preferred as activated oxygen (03) is heavier than air. Increasing the elevation
increases the performance of the purifier.
8. Plug unit into an appropriate (three prong grounded) outlet. Be sure the power switch on the rear of unit is in the “ON”
position.
2
Hospital-Grade HEPA Filter
4
Photo-Catalytic Filter
Activated Oxygen
O
3
Plate
1
Dirt, Dust & Debris Pre-Filter
Rear Diagram
CORRECT INSTALL
INCORRECT INSTALL
TAB LOCATION
3
Activated Carbon Filter
(2) Germicidal UV bulbs