BOTTOM PANEL
Signal Input PD1-PD2
There are 2 sets of inputs to receive Tamper or Intruder signal from Zone
1 to 2. Please clean the connectors prior to connecting the SC connectors
into their respective socket here. Do not stare into the sockets and
6
Light Source Out LD1-LD2
This is the output for the light source to send its light pulse into the
connection. Do not stare into the output at any time during operation to as it
can caused permanent damaged to the eye.
5
Dry contact
Status
NO1 & CC1
TO1 & TC1
NO2 & CC2
TO2 & TC2
Power off
Shunt
Shunt
Shunt
Shunt
Normal
Open
Open
Open
Open
CH1 TAMPER
Open
Shunt
N/A
N/A
CH1 INTRUDER
Shunt
Open
N/A
N/A
CH2 TAMPER
N/A
N/A
Open
Shunt
CH2 INTRUDER
N/A
N/A
Shunt
Open
Table 1 Dry contact status
6
N
S
C
o
n
tr
o
lle
r
Cleaning of SC/ APC Connectors
Upon removing the covers, the SC/ APC connector can be accessed.
Each SC/ APC connectors are to be cleaned individually with 99% alcohol
and lint-free clean swipes.
connectors at all time to prevent permanent damaged to the user’s eyes.