Nxtar NS200M Instructions Manual Download Page 2

Thank you for purchasing the NXTAR NS200M 
Security Controller. This remarkable component 
has been engineered to provide its user with may 
year of reliable sensing capabilities utilizing fiber 
optics as its medium. Please take a few minutes 
to read this manual thoroughly before you 
connect and operate the NS200M.

As the operation may be multi-layered and the 
configuration options are very flexible, you are 
encouraged to discuss the requirements with your 
NXTAR Specialist in your country for technical 
assistance. 

Perimeter Intruder Detection System

INTRODUCTIONS

FEATURES

In

s

ta

lla

tio

n

 –

N

S

 C

o

n

tr

o

lle

r

2

2 Zones

2 Individually calibrated zones to cover a
maximum of 600m of perimeter on fence
deployment , Powered by extremely high
powered, stable light source, to give you
constant and maintenance-free performance ,
all these housed in a strong cast aluminum
casing.

Intelligent Discrimination

High performance software to calibrated the
zones individually and the ability to monitor
them

simultaneously.

Equipped

with

Intelligent discrimination to help eradicate
Nuisance

Alarm and False Alarm to the

lowest

possible

industrial

standard.

The

NS200M is also able to identify the presence
of Global Noises without the presence of

weather station

100% Passive Outfield

NXTAR Systems is one of the few who is
able to achieve a 100% passive components
outfield. Our systems doesn’t require any
electrical powering once outfield. This is a
very strong feat as it requires no deployment
of electrical cables for powering and signal
amplification for long distance transmission.

It also enabled deployment within a faster.

Plug and Play   

NXTAR enables the user and installer to
connect all fiber optics with SC connectors.
There is no need to expensive and fragile
splicer to connect the fiber cables to their

r e s p e c t i v e j u n c t i o n s / t e r m i n a l b o x e s .

N

S

 C

o

n

tr

o

lle

r

Summary of Contents for NS200M

Page 1: ...Instruction NS Controller Perimeter Intruder Detection System Model NS200M Security Controller NS Controller...

Page 2: ...housed in a strong cast aluminum casing Intelligent Discrimination High performance software to calibrated the zones individually and the ability to monitor them simultaneously Equipped with Intellig...

Page 3: ...zoom in on its present location to see and record the intrusion We at NXTAR understand that it is almost impossible to demand a perimeter especially a big one to be of the same landscape and environme...

Page 4: ...Fiber or Sens ing Fiber User c an refer to Installation System Setting and Calibration for more details required Necessary action should be carried out while the respective TO TC contacts will also b...

Page 5: ...sence of intruder in one of the zone TAMPER There are 2 sets of dry contacts in this row It is labeled TO1 TC1 to TO2 TC2 to trigger other devices of Zone 1 to 2 respectively if there is a tampering i...

Page 6: ...into the output at any time during operation to as it can caused permanent damaged to the eye 5 Dry contact Status NO1 CC1 TO1 TC1 NO2 CC2 TO2 TC2 Power off Shunt Shunt Shunt Shunt Normal Open Open O...

Page 7: ...Perimeter Intruder Detection System SYSTEM STRUCTURE Installation NS Controller ZONE 1 ZONE 2 Leading Fiber Sensing Fiber Controller SJB 7 NS Controller TJB Sensing Fiber...

Page 8: ...The tip of the SC connectors are made of ceramic and are not to be touched by bare fingers When connecting please ensure that the tip does not touch the sides of the sockets 4 Turn system on and wait...

Page 9: ...X 01pc 2 Relay Contact i 120Vac 10A 250Vac 7A ii 24Vdc 10A 3 Intruder LED x 02 4 Tamper LED x 02 5 Beeper x 01 9 NS Controller 5 Beeper x 01 Mechanical Spec 1 Dimension 260mm x 205mm x 44 6mm L x W x...

Page 10: ...Perimeter Intruder Detection System DIMENSION Installation NS Controller 10 NS Controller...