![NXP Semiconductors SLN-LOCAL2-IOT User Manual Download Page 34](http://html.mh-extra.com/html/nxp-semiconductors/sln-local2-iot/sln-local2-iot_user-manual_1721901034.webp)
Figure 34. Opening Flash GUI Tool for Application/CA certificates
The GUI Flash Tool automatically fills in the fields associated with the project that must be changed. Select the “File
System...” button, which opens the window, as shown in
. Within that window, navigate to the application certificate
(app_crt.bin) and the CA (ca_crt.bin) that were recovered from the device or generated following the instructions in
Figure 35. Selecting the Application/CA certificate binaries
Within the “Base Address” textbox, enter “0x61D00000” and “0x61D80000” (must be done for both) for the certificate (app_crt.bin)
or “0x61CC0000” for the certificate authority public certificate (ca_crt.bin) and click the "Run" button. In
, for
demonstration purposes, the same app_crt.bin certificate is used for both banks. For security reasons, using different certificates
for each bank is recommended.
NXP Semiconductors
Building and programming with MCUXpresso
SLN-LOCAL2-IOT Developer’s Guide, Rev. 0, 19 April 2021
User's Guide
34 / 87