Figure 10. BYPASS and IDCODE check
7. Click the SAMPLEall button, and you will see No result becomes Test done. Double click the entity name, and the
BSDL.SET window appears, as shown in
.
Figure 11. SAMPLE check
8. In the BSDL.SET window, uncheck Intern to filter out the internal registers. The remaining contents are the sampled value
on each signal pins. Use a multimeter to measure voltage of at least three signal pins, and see if the logic state matches
the sampled value. SAMPLE check pass,
NXP Semiconductors
BSDL file validation using Lauterbach JTAG debugger
Introduction to Boundary Scan of i.MX RT Series, Rev. 1, March 2, 2021
Application Note
10 / 15