NVR SYSTEMS DZE2 Manual Download Page 6

7.1.10. SET button:

This button can set delay auto-closing time and boom horizontal and 
vertical fine adjustment.

Power-oFFfirstly, pressing and holding SET button then power on, if the 

Function Indicator constant lighting means delay auto-closing function is 

o

FF

; if twinkling, the twinkling times is the seconds of the delay auto-

closing.
Opening method: Press UP button (of the remote controller) to open this 

function, after open, the delay auto-closing time is 3 seconds, each pre
ssing of the UP button increases by 1 second, 
the max is 60 seconds.
Closing method: Press STOP button, the Function 
Indicator constant lighting means close. 
Read seconds: Press DOWN button, the Function
 Indicator twinkling times is the seconds of the 
delay auto-closing.
Release the SET button to save and start working. 
(Note: During setting, please don't release SET button)

Boom vertical 
adjustment

8. Common Malfunctions and Solutions

8.1. When power-on, press “UP” or “DOWN” button, there is no reaction 
on the boom.

8.1.1. Check up the power supply and the fuse.
8.1.2. Check if the remote controller matches the radio receiver; or check up 
the battery inside and then change it if it is lack of power.
8.1.3.  Check  whether  there  is  co-channel  interference,  and  press  the  buttons 
on the control board to check if can work.
8.1.4.  Check  up  if  the  external  protection  circuit  is  failure  or  in  protection 
status. Check up the condition of photocell and loop detector are lighting.

8.2. The barrier gate closes half, and then stop learning, during controller 
self-test after power-on.

 

8.2.1.  Check  up  if  the  boom  is  installed,  the  barrier  gate  need  to  work  with 
boom if springs installed. 

8.3. Fence boom or 6m boom lifts up automatically when closing.

8.4.1. Set DIP Switch 1 to be OFF position.

9.1.  Free  service  is  oFFered  for  component  parts  in  one  year  warranty  time. 
(not includes the barrier boom or remote)
9.2. Lifetime service with charge accordingly.
9.3. Technical questions are supported.
9.4.  The  below  items  and  situations  are  not  included  in  the  range  of  free 
service:
9.4.1. The  user  does  not  follow  the  instruction  and  cause  any  damage  of  the 
product.
9.4.2. The  power  supply  is  not  stable,  over  the  range  of  permitted  voltage  or 
not accordant to safety electric using standard.
9.4.3. The user installs or uses the product in wrong methods, cause damage to 
the appearance of product.
9.4.4. Natural disaster causes damage to the product.
9.4.5. Warranty time is over.
9.4.6. Service items are out of our promises.

9. Warranty and Service Items

ON, means the barrier will only open slowly (for longer fence boom).

7.1.9. Boom up angle setting:

Counterclockwise to the end is 60

°

, clockwise to the end is 90

°

, mid

dle is end is 60

°

~85

°

.

Boom horizontal and vertical fine adjustment

Horizontal adjustment: In UP limit status, pressing 
and holding SET button, then press UP button
 (of the remote controller) (if angle over 90

°

) or 

DOWN button (if angle less than 90

°

) to adjust 

the value (0~25). Release the SET button, the adjustment I
s done when the boom open to the UP limit status next time.
Vertical adjustment: In DOWN limit status, pressing and 
holding SET button, then press OPEN button (of the remote 
controller) (if angle less than 0

°

) or  DOWN button (if angle over 0

°

to  adjust  the  value  (0~40).  Release  the  SET  button,  the  adjustment  is 
done when the boom close to the DOWN limit status next.
(Note:  During  adjusting,  when  press  STOP  button,  the  twinkling  times 
of the Function Indicator means the current adjusted value.)

7.2. Controller auto-detect after power-on description.

The  controller  should  be  learning  the  position  of  boom  after  power-on:  The 
barrier  gate  will  open  and  then  close  slowly  one  time  by  default.  During 
learning process, it detects all open and anti-bumping signal interface, and it 

Boom horizontal
 adjustment

will stop learning if there is signal. After finish leaning, the boom stays at the 
down limit position. 
The buzzer will sound 1 long and 5 short error, if the barrier installed spring 
but no boom, or there is obstruction on the boom during up or down process, 
or the spring and boom in serious imbalance, need to remove the obstruction 
or adjust the spring, then power-on again. 
If  learning  mode  is  MBoom  up  only”,  the  barrier  gate  will  open  to  up  limit 
position, and not close; during learning process of opening, if the barrier can't 
open to up limit position due to obstruction, and can't close normally, need to 
power on learning again.

8

.

  

.

9

.

  

.

Delay auto-closing setting

Summary of Contents for DZE2

Page 1: ...r reference only the product prevails in kind Servo Barrier Controller Warning When power oFF there is still high voltage inside the control board before the indicator light goes out So please do not...

Page 2: ...ology and machinery processing technology no limit switch design to realize non adjust of mechanism adjustable speed automatic speed reduction ext In this way make the barrier operate more steadily an...

Page 3: ...s unscrew the M8 140 spring adjusting screws by a hexagonal spanner then take o the spring The steps for installation and disassembly the spring are the opposite 6 2 3 Spring force adjustment When pow...

Page 4: ...anism installation direction disassemble 6 sets 8MM screws for xing the mechanism panel turn the mechanism 180 degrees vertically and put back into the cabinet And then x it with the 6 sets screws 6 3...

Page 5: ...tatus next time Note During adjusting when press STOP button the twinkling times of the Function Indicator means the current adjusted value 7 1 Controller interface explanations All the electrical con...

Page 6: ...oduct 9 4 2 The power supply is not stable over the range of permitted voltage or not accordant to safety electric using standard 9 4 3 The user installs or uses the product in wrong methods cause dam...

Page 7: ...ing breaking due to excessive fatigue 10 4 Check the easily worn out parts every half year and renew it 10 5 Remote control distance will be shortened or not work in cases like big object screening ba...

Page 8: ...or press 2 times continuously indicator of receiver ashes 4 times That means learning well If the remote controller doesn t receive any eFFective signal it will quit learning status Clear the code of...

Reviews: