7.1.10. SET button:
This button can set delay auto-closing time and boom horizontal and
vertical fine adjustment.
Power-oFFfirstly, pressing and holding SET button then power on, if the
Function Indicator constant lighting means delay auto-closing function is
o
FF
; if twinkling, the twinkling times is the seconds of the delay auto-
closing.
Opening method: Press UP button (of the remote controller) to open this
function, after open, the delay auto-closing time is 3 seconds, each pre
ssing of the UP button increases by 1 second,
the max is 60 seconds.
Closing method: Press STOP button, the Function
Indicator constant lighting means close.
Read seconds: Press DOWN button, the Function
Indicator twinkling times is the seconds of the
delay auto-closing.
Release the SET button to save and start working.
(Note: During setting, please don't release SET button)
Boom vertical
adjustment
8. Common Malfunctions and Solutions
8.1. When power-on, press “UP” or “DOWN” button, there is no reaction
on the boom.
8.1.1. Check up the power supply and the fuse.
8.1.2. Check if the remote controller matches the radio receiver; or check up
the battery inside and then change it if it is lack of power.
8.1.3. Check whether there is co-channel interference, and press the buttons
on the control board to check if can work.
8.1.4. Check up if the external protection circuit is failure or in protection
status. Check up the condition of photocell and loop detector are lighting.
8.2. The barrier gate closes half, and then stop learning, during controller
self-test after power-on.
8.2.1. Check up if the boom is installed, the barrier gate need to work with
boom if springs installed.
8.3. Fence boom or 6m boom lifts up automatically when closing.
8.4.1. Set DIP Switch 1 to be OFF position.
9.1. Free service is oFFered for component parts in one year warranty time.
(not includes the barrier boom or remote)
9.2. Lifetime service with charge accordingly.
9.3. Technical questions are supported.
9.4. The below items and situations are not included in the range of free
service:
9.4.1. The user does not follow the instruction and cause any damage of the
product.
9.4.2. The power supply is not stable, over the range of permitted voltage or
not accordant to safety electric using standard.
9.4.3. The user installs or uses the product in wrong methods, cause damage to
the appearance of product.
9.4.4. Natural disaster causes damage to the product.
9.4.5. Warranty time is over.
9.4.6. Service items are out of our promises.
9. Warranty and Service Items
ON, means the barrier will only open slowly (for longer fence boom).
7.1.9. Boom up angle setting:
Counterclockwise to the end is 60
°
, clockwise to the end is 90
°
, mid
dle is end is 60
°
~85
°
.
Boom horizontal and vertical fine adjustment
Horizontal adjustment: In UP limit status, pressing
and holding SET button, then press UP button
(of the remote controller) (if angle over 90
°
) or
DOWN button (if angle less than 90
°
) to adjust
the value (0~25). Release the SET button, the adjustment I
s done when the boom open to the UP limit status next time.
Vertical adjustment: In DOWN limit status, pressing and
holding SET button, then press OPEN button (of the remote
controller) (if angle less than 0
°
) or DOWN button (if angle over 0
°
)
to adjust the value (0~40). Release the SET button, the adjustment is
done when the boom close to the DOWN limit status next.
(Note: During adjusting, when press STOP button, the twinkling times
of the Function Indicator means the current adjusted value.)
7.2. Controller auto-detect after power-on description.
The controller should be learning the position of boom after power-on: The
barrier gate will open and then close slowly one time by default. During
learning process, it detects all open and anti-bumping signal interface, and it
Boom horizontal
adjustment
will stop learning if there is signal. After finish leaning, the boom stays at the
down limit position.
The buzzer will sound 1 long and 5 short error, if the barrier installed spring
but no boom, or there is obstruction on the boom during up or down process,
or the spring and boom in serious imbalance, need to remove the obstruction
or adjust the spring, then power-on again.
If learning mode is MBoom up only”, the barrier gate will open to up limit
position, and not close; during learning process of opening, if the barrier can't
open to up limit position due to obstruction, and can't close normally, need to
power on learning again.
8
.
.
9
.
.
Delay auto-closing setting