Contents
1. Brief Introduction...............................................................1
2. Functions and Features........................................................1
3. Technical Data....................................................................1
4. Mechanism Structure..................................................................2
5. Installation Direction Definition...........................................2
6. Mechanical Part Installation and Adjustment..............................3
6.1. Cabinet Installation.............................................................3
6.2. Spring Selection, Installation and Adjustment.......................3
6.3. Mechanism Installation Direction Change ............................4
7. Controller Explanations and Instructions .................................... 6
7.1. Controller Interface Explanations......................................... 7
7.2. Controller Auto-Detect after Power-On Description............... 8
8. Common Malfunctions and Solutions.......................................... 9
9. Warranty and Service Items.........................................................9
10. Maintenance...........................................................................10
11. Packing List............................................................................10
I. Spring Selection Table...............................................................11
II. Remote Control Coding............................................................12
III. Wiring Diagram for R&G Light Interface..................................13
IV. Drive Requirement for Main Control Board Wire Control......13
1. It is forbidden to open the barrier cabinet top cover or door when it
is working.
2. There must be a grounding connection for the barrier cabinet.
3. Make sure there is no person or any obstruction under the boom
when it is falling.
4. Before delivery, the barrier gate spring and the boom length are
well-balanced. It is not allowed to change the boom length randomly.
If needed, please check with the technician.
Warning!
For safety, please do follow the instruction strictly to manage this
product:
This is our newly-produced DC servo barrier gate, which utilizes
the updated electronic control technology and machinery processing
technology, no limit switch design, to realize non-adjust of
mechanism, adjustable speed, automatic speed reduction, ext. In
this way, make the barrier operate more steadily and more reliably.
This product is highlighted in frequency applications and longer
lifetime.
2.1. No clutch design: open the barrier gate by manual hand wheel
when power of.
2.2. No limit switch design: the motor can detect the boom position
automatically.
2.3. Bi-direction boom holder design: left-installation and right-
installation can be exchanged easily and quickly.
2.4. Self-detect after power-on, open/close speed is adjustable.
2.5. With auto-reversing on obstruction function.
2.6. Infrared photocell interface is available. (need to install
photocell device).
2.7. Loop detector interface is available, to avoid hitting the vehicle,
and control the boom falling down automatically after vehicle
passing. (need to install loop detector)
2.8. Built-in delay auto-closing function, coordinated with counting
function, if the numbers of vehicle passed less than the stored
numbers, the boom will fall down automatically by countdown, but
will be new countdown if there is up or loop detector signal.
2.9. With auto-aging test function.
2.10. NO/NC wire control signal input are optional.
3.1. Working temperature (motor): -35
°
C~ + 85
°
C
3.2. Working Power: 220V±10%, 110V ±10%
3.3. Motor Power: 120W MAX
3.4. Humidity: 90% RH
3.5. Distance of remote control: L≥30M
3.6. Insulation Grade: F
2. Functions and Features
3. Technical Data
1. Brief Introduction
1
.
.