  nVent.com/RAYCHEM

(8) Extra codes

000

Without extra code

214

Math and logic module

221

Structured text

a

  The language of the device texts can be adjusted (German,    

   English, French, Spanish).

b   

The options cannot be retrofitted! Please consider options    

   when ordering.

c   

PhotoMOS is a registered trademark of Panasonic  

 

   Corporation.

(1)

(2)

(3) (4) (5) (6)

(7)

(8)

Order code

/

,  ...

a

3 Order 

example

702114 /

8 – 4

3

5

6

– 23 / 214 ,  ...

a

  List extra codes in sequence, separated by commas.

1.5.3  Scope of delivery

1 device in the ordered version
1 quick start guide
1 mounting frame 

1.5.4  Accessories

Description

Setup program
USB cable, A connector to Micro-B connector, length 3 m
Mounting for DIN rail, for type 702111

1.6 

Brief description

 

The controller series comprises five freely configurable,  

 

 

universally usable compact controllers in various DIN formats to  

 

control temperature, pressure, and other process variables.

 

The devices are characterized by a simple, clearly structured    

 

operation supported with texts. Process values and parameters  

 

are represented by two 18-segment LCD displays. In addition,   

 

all devices have individual display elements for the switch  

 

 

positions of the outputs as well as for manual mode, ramp  

 

 

function, and timer. The devices are operated using a membrane  

 

keyboard with four buttons and can be used under harsh  

 

Summary of Contents for 00123456

Page 1: ...TCONTROL 05 PANEL MOUNTED CONTROLLER...

Page 2: ...nt conditions 11 2 2 Cleaning 11 2 3 Dimensions 12 2 4 DIN rail installation 12 2 5 Panel mounting 13 3 Electrical connection 14 3 1 Installation notes 14 3 2 Connection elements 15 3 3 Connection dia...

Page 3: ...ymbol in connection with the signal word indicates that material damage or data loss will occur if the respective precautionary measures are not taken CAUTION This symbol indicates that components cou...

Page 4: ...taking the technical documentation provided into account Risks resulting from the application may arise e g as the result of missing safety provisions or wrong settings even when the device is used pr...

Page 5: ...lectrostatic discharge ESD ESD electrostatic discharge To prevent damage due to ESD electronic modules or components must be handled packaged and stored in an ESD protected environment Measures that p...

Page 6: ...ulations for waste treatment and disposal Disposing of the packaging material The entire packaging material cardboard packaging inserts plastic film and plastic bags is fully recyclable 1 5 Identifyin...

Page 7: ...igital input 1 alternative to logic output 2 relays N O contact 1 logic output 0 14 V alternative to digital input 1 incl timer ramp function and program function 2 Version 8 Standard with default set...

Page 8: ...essories Description Setup program USB cable A connector to Micro B connector length 3 m Mounting for DIN rail for type 702111 1 6 Brief description The controller series comprises five freely configu...

Page 9: ...user has the option to create his her own application using structured text ST code The devices can be conveniently configured using a PC with the help of the setup program incl program editor and ST...

Page 10: ...8 Device types TCONTROL 05 1 9 Available technical documentation In addition to this quick start guide the following documents are available as PDF files and can be requested Operating manual Interfa...

Page 11: ...cal data Aggressive gases and vapors have a negative effect on the operating life of the device The mounting site must be free from dust powder and other suspended solids Installation position The dev...

Page 12: ...tached to the DIN rail and a device holder see depictions in the section Dimensions Process 1 Mount the base plate on the DIN rail from above and press down until it engages 2 Insert the mounting fram...

Page 13: ...ng TCONTROL 05 1 2 1 Insert the device from the front into the panel cut out and ensure that the seal is correctly positioned 2 Push the mounting frame from the panel rear onto the device body and pre...

Page 14: ...separately and not parallel to one another Only use shielded and twisted probe and interface cables Do not route the lines close to current carrying components or cables For temperature probes ground...

Page 15: ...and that it is only possible for qualified personnel to define settings Please observe the corresponding safety regulations in this context References to other information The electromagnetic compati...

Page 16: ...utput 5 relay logic or analog output L1 L N L Voltage supply Setup USB PC setup program 3 3 Connection diagram CAUTION In unfavorable conditions the temperature may exceed 60 C at the terminals and to...

Page 17: ...6 I x A S E Current DC 0 4 20 mA U x 6 6 7 7 5 5 7 5 6 7 5 6 7 7 7 7 8 7 6 I x A S E Resistance potentiometer two wire circuit U x 6 6 7 7 5 5 7 5 6 7 5 6 7 7 7 7 8 7 6 I x A S E Resistance potentiom...

Page 18: ...x Ix U 13 14 3 3 4 Digital output Output Version Symbol and terminal designation 1 Relay N O contact 1 2 3 4 2 Relay N O contact for type 702110 as option 2 see below 1 2 3 4 3 Logic output 0 14 V usa...

Page 19: ...s case the standard digital outputs are activated and the digital outputs of the options are deactivated 3 4 Galvanic isolation 1 The voltage specifications correspond to the test voltages alternating...

Page 20: ...play and control elements 1 18 segment LCD display e g actual value 4 digit white also for displaying menu items parameters and text 2 18 segment LCD display e g setpoint value green also for displayi...

Page 21: ...active The outputs can be manually controlled using the Up and Down buttons Increase de crease output level or three step controller Open close actuator Button functions Button or button combination...

Page 22: ...enu for level inhibit 4 2 Language selection After switching on the device for the first time the user can either confirm the flashing displayed language with OK or select another language using the U...

Page 23: ...ta In the event of an error the controller switches to manual mode 4 4 Further information For further information regarding the operation and configuration of the device see the operating manual as w...

Page 24: ...2014 IEC 60584 1 2013 ITS 90 270 to 400 C 0 25 from 150 C NiCr Ni K DIN EN 60584 1 2014 IEC 60584 1 2013 ITS 90 270 to 1300 C 0 25 from 80 C NiCr CuNi E DIN EN 60584 1 2014 IEC 60584 1 2013 ITS 90 270...

Page 25: ...e Ambient temperature influence 100 ppm K Cold junction Internal or external constant Reference point temperature external 0 to 100 C adjustable Sampling rate 150 ms Input filter Digital filter 2nd or...

Page 26: ...all measuring spans lead to reduced linearization accuracy Ambient temperature influence 100 ppm K Connection type Resistance transmitter Resistance potentiometer Three wire circuit Two wire three wir...

Page 27: ...erflow Measuring range overflow Short circuit probe line Break probe line Polarity RTD temperature probe Resistance potentiometer Resistance transmitter a b Thermocouple c Current 0 to 20 mA Current 4...

Page 28: ...00 operations at rated load 350 000 operations at 1 A Relay N O contact with longer contact life Switching capacity Contact life Max 3 A at AC 230 V resistive load 300 000 operations at rated load 1 5...

Page 29: ...Upper display 4 lower display 8 Decimal places 0 1 2 3 or automatic configurable 5 7 Electrical data Voltage supply AC 110 to 240 V 10 15 48 to 63 Hz AC DC 20 to 30V 48 to 63Hz Voltage supply Accordi...

Page 30: ...2 According to class 2M2 According to class 3M3 Electromagnetic compatibility EMC Interference emission Interference immunity According to DIN EN 61326 1 Class A only for industrial use Industrial req...

Page 31: ...ssanschluss 0 0 0 0 0 0 Nuts Mutter 0 0 0 0 0 0 Screw Schraube 0 0 0 0 0 0 SJ T 11364 This table is prepared in accordance with the provisions SJ T 11364 o GB T 26572 Indicate the hazardous substances...

Page 32: ...nt com Italia Tel 39 02 577 61 51 Fax 39 02 577 61 55 28 salesit nVent com Lietuva Latvija Eesti Tel 370 5 2136633 Fax 370 5 2330084 info baltic nVent com Magyarorsz g Tel 36 1 253 7617 Fax 36 1 253 7...

Reviews: