Seite 8 von 17
0800000790 / Stand: 3/ Ausgabedatum: 24.04.2018
Rev.B
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 • nVent.com/HOFFMAN
P/N 89128258
0800000790
�
Mounting to control enclosure by using panel coupling
8 x M5 / Ø 5.5
At least 4 bolting points
must be used:
- 100 x 100
- 75 x 75
4x M5x16
Tightening torque 6 Nm
�
Mount the panel coupling with lock
washers and screws
When using panel coupling components, always ensure that the stability of the
mounting surface is suitable for mounting.
Attention
Screwing the clamping lever
Lock Actuator
�
Insert the Lock Actuator in the threaded bore
�
Screw the clampling lever
Lock Actuator
Indication: Mounting of the component “Panel coupling W” is illustrated below
Lock Actuator
60
75
100
60
75
100