Directory

 

Directory___________________________________________________________________________________________________  3
Indication and Use of the instructions ___________________________________________________________________________  3
Safety instructions ___________________________________________________________________________________________  3
Mechanical Data ____________________________________________________________________________________________  4
Load diagram for static load capacity CS-3000 neXt ________________________________________________________________  4
Installation and adjustment ___________________________________________________________________________________  4
  Mounting to plant or machine _______________________________________________________________________________  4
  Tube mounting vertically ____________________________________________________________________________________  5
  Tube mounting horizontally _________________________________________________________________________________  5
  Vertical tube adjustment (also possible later) ___________________________________________________________________  6
  Horizontal tube adjustment (also possible later) _________________________________________________________________  6
Mounting to enclosure _______________________________________________________________________________________  7
  Mounting to control enclosure by using coupling or elbow coupling ________________________________________________  7
  Mounting to control enclosure by using adapter (narrow sections) __________________________________________________  7
  Mounting to control enclosure by using panel coupling ___________________________________________________________  8
Screwing the clamping lever ___________________________________________________________________________________  8
Modification of firmness ______________________________________________________________________________________  9
Joint cap mounting and  dismounting ___________________________________________________________________________  9
Attitude of the tightness of torque (M) ___________________________________________________________________________ 10
Accessories _________________________________________________________________________________________________ 11
Tube Cutoff _________________________________________________________________________________________________ 14
Earthing ___________________________________________________________________________________________________ 15
Earthing example ____________________________________________________________________________________________ 17

The sequence of the chapters is not necessarily the operation or assembly sequence.

Not all chapters apply for each component.

Indication:

 

 

Pick out the pictogram for the corresponding component shown on the title page

 

You will see in the chapters pictograms for which the mounting step applies

 

Mounting starts with the plant, machine or wall mounting and the corresponding chapter

    Do not reach into the tubes

    The excessive crushing, stretching and bending of power lines has to be avoided.

    The power line system has to be checked for abrasion points regularly.

    Mounting or the electrical connection of the power line system must be carried out by a qualified electrician.

     Do not damage seals during installation as otherwise the technical characteristics cannot be complied with.

    

When using panel coupling components, always ensure that the stability of the mounting surface is suitable  

for mounting.

   

 The coupling components are designed for mounting centrally on the control enclosure. 

Off-center installation is not permitted.

    The tightening torques of the screw connections should be inspected on a regular basis.

Indication and Use of the instructions

Safety instructions

Attention

Attention

Attention

Attention

Attention

Attention

Attention

Attention

Summary of Contents for SYSPEND 180-MAX

Page 1: ...0000790 Installation and Operating Instructions Suspension System SYSPEND 180 MAX Component pictograms Narrow Adapter Flange Coupling Flange Elbow Coupling Vertical Panel Coupling Horizontal Panel Cou...

Page 2: ...tum 24 04 2018 Rev B 2018 Hoffman Enclosures Inc PH 763 422 2211 nVent com HOFFMAN P N 89128258 0800000790 oder oder oder oder This component can either be mounted on the wall or be operated as a stan...

Page 3: ...________________________________________________________________________ 8 Modification of firmness_______________________________________________________________________________________ 9 Joint cap m...

Page 4: ...not avoided it is possible that problems of load adjustment and protection class arise including intermediate joint Length of the extension arm Installation and adjustment Mechanical Data Mounting to...

Page 5: ...nt Fit the screw 1 2 until a noticeable resistance Should the seal not be crushed visibly press the tube further on the component Fit the screw 5 6 and check the vertical support tube alignment with a...

Page 6: ...screw 3 6 Tighten the screw 5 6 until the desired position is reached Tighten the screw 3 6 with 30 Nm Loosen the screw 3 6 Tighten the screw 5 6 until the desired position is reached Tighten the scre...

Page 7: ...o the coupling and tighten them with 6 Nm At least 4 bolting points must be used 100 x 60 95 x 40 60 x 60 Partial representation of the control enclosure 1 2 4x M6 x 16 Tightening torque 6 Nm Mounting...

Page 8: ...0 75 x 75 4x M5x16 Tightening torque 6 Nm Mount the panel coupling with lock washers and screws When using panel coupling components always ensure that the stability of the mounting surface is suitabl...

Page 9: ...or decrease resistance Factory preset to optimum torque setting Modification of firmness Joint cap mounting and dismounting Adjustment screw M6 Indication Mounting and dismounting of the component el...

Page 10: ...er fixing the threaded sleeve If the resistance is accomplished in completely installed condition accepts BERNSTEIN AG no liability for breakage personal injury or fall of the system Attention 5 Abb 4...

Page 11: ...of the swivel angle limiter is illustrated below by the component coupling Dismounting of the dust cap In order to limit the swivel angle to the left turn the buttom of the coupling to the right In o...

Page 12: ...he component elbow coupling For removal of cover see page 9 Unscrew the locking tappet and remove it In order to limit the swivel angle to the left turn the buttom of the coupling to the right In orde...

Page 13: ...mp connecting tube into the suitable shaft and fix it with nut SW27 Screw the signal lamp part on the connecting tube Refit the cover again on the component Article number Type S1MSLAR Set of signal l...

Page 14: ...Inc PH 763 422 2211 nVent com HOFFMAN P N 89128258 0800000790 2 Holes 4 Holes M10 8 5 4 M10 8 5 4 Tube Cutoff 1 2 The original operating and installation instructions are the German language version O...

Page 15: ...The design of the protective conductor system must be in accordance with UL Standard UL 508A paragraph 14 Earthing Fixing positions for earth screws M5 M5 M5 M4 M5 M5 M5 M5 M5 M5 M4 M5 M5 M5 M5 M5 M5...

Page 16: ...763 422 2211 nVent com HOFFMAN P N 89128258 0800000790 M5 M5 M4 M5 M5 M5 M5 M5 M5 M5 M4 M5 M5 M5 M5 M5 M4 M5 M5 M5 Rotatable Elbow S1MER Rotatable Elbow S1MER Intermediate Joint S1MIJ Vertical Wall Jo...

Page 17: ...sion system with moving parts it should be ensured that the chosen cable length permits these movements Cable crimp Earthing conductor Earthing conductor Earthing continuity screw Serrated contact was...

Reviews: