CLEANING AND DISINFECTING

Remove all accessories (including nebuliser, mask, mouthpiece, connector, outer 

cover) from the device after each use.
Open the cover of nebuliser and remove the residual liquid. You are advised, 

after each use, to allow the device running with clean water instead of liquid for 

1-2 minutes in order to clean the nebulising head. Clean the mask, mouthpiece, 

connector, outer cover, and nebuliser gently (Note that the main unit should not be 

washed).
Immediately after completion of cleaning, dry the accessories with medical gauze. 

Note that the metal mesh in nebulising head must not be touched strongly any 

sharp and rough object. Dry the water inlet and outlet of the nebulising head with 

medial swab gently.
If there is dust on the surface of main unit, please wipe it up with wet and dry gauge 

successively.
After completion of cleaning, store the device in clean storage bag.

1. 

2. 

 

 

 

3. 

 

 

4. 

5.

Cleaning

Rinse the mask, mouthpiece, connector and outer cover with medical alcohol (not 

including the MESH HEAD); rinse with water; dry with medical gauze.
Disinfecting the nebulising head: gently clean the metal mesh and electrode in 

the nebulising head with a medical swab dipped with medical alcohol; rinse the 

nebulising head with water; dry the surface of nebulising head with medical swab as 

soon as possible by patting action.
Boiling disinfection for the following accessories: 

Mouthpiece, connector and outer cover: put in a boiling steriliser with sufficient 

water to ensure they are completely submerged; heating the water to boiling point 

(for 20 minutes in total); dry them with medial gauze.
Boiling Disinfection must NOT be used for the following parts: 

Nebuliser, nebulising head, main unit, mask, power adapter, storage bag, and 

packaging bag.

1. 

2. 

 

 

3. 

 

 

4.

Disinfecting

Make sure there is no residual liquid in nebuliser.
Make sure the nebuliser has been cleaned and sterilised thoroughly after each use.
Store the device and its parts. Components, and accessories in a clean and safe place.
Protect the device against direct sunshine and shock. Remember to keep any 

heating device and open fire far away from the storage place.
Protect the device against contact with any corrosive liquid.
Never dry the device and its parts and components in a microwave oven.
Never wrap any power cord around the main unit.




• 



STORAGE AND MAINTENANCE

Summary of Contents for 5076

Page 1: ...EN Portable nebuliser with MESH technology 5076...

Page 2: ...Manufacturer Low battery indicate Power indicate light Keep away from sunlight Type BF Applied Part Read instructions carefully Keep in a cool dry place Operating instructions Symbol for the marking o...

Page 3: ...molecular density such as drugs based on hyaluronic acid To preserve the pores of the nebulizing plate and to avoid clogging it is advisable to avoid the use of physiological hypertonic solution due t...

Page 4: ...9 10 11 12 13 14 a b 15 Adult Mask Child Mask Adapter Optional Power Plug Adapter Connector Storage bag PREPARATION BEFORE USE Use the Battery Open the battery cover in the bottom of the main unit al...

Page 5: ...ning and disinfecting To avoid cross infection all users of a same device should each be provided with a set of nebulizer and accessories The nebulizers and accessories for different users should be s...

Page 6: ...left hand and close the nebuliser cover with your right hand press the lock downwards with the thumb to the point when you hear a clicking sound that indicates a good closing state 5 Reinstall the Ou...

Page 7: ...sal cavity it is recommended to take a long breath through nasal cavity and then exhale through mouth In case of medication through throat it is recommended to take breath through mouth and then exhal...

Page 8: ...nds depending on the liquid type When there is not much liquid left you may tilt the device towards yourself to allow liquid gathered at the nebulising head side in order to make full use of the resid...

Page 9: ...ting the nebulising head gently clean the metal mesh and electrode in the nebulising head with a medical swab dipped with medical alcohol rinse the nebulising head with water dry the surface of nebuli...

Page 10: ...our doctor No tap water or boiled water can be used The container for preparation of liquid must be boiling sterilised The duration limit for each use of the device should be no more than 15 minutes o...

Page 11: ...vice does not work Incorrect installation of nebuliser Reinstall the nebuliser correctly Dirt on and in the nebuliser is serious Clean the nebuliser replace nebulising head if necessary The liquid can...

Page 12: ...y Life 90 minutes supplied by two AA Alkaline Battery Automatic Shutdown Automatic shutdown without liquid Operating Temperature and humidity Air pressure 10 C 40 C 85 R H 700hPa to 1060hPa Storage Te...

Page 13: ...d as consumable e g batteries brush heads or parts subject to usury The legal guarantee of 24 months is void if 1 2 3 The product has undergone aesthetic damage due to improper use not in accordance w...

Reviews: