21
Select “
MOTION SETUP
” and push the
Joystick
to the left or right. Then the MOTION setup
displays.
MOTION SETUP
SENSITIVITY: 10
RESOLUTION : 02
POSITION : ALL
DELAY : 00 SEC
OUTPUT : OFF
HOLD TIME : 03 SEC
EXIT(ESC TO EXIT)
Set
SENSITIVITY
00 ~ 20
Set
RESOLUTION
01 ~ 04
Set
POSITION
ALL, CENTER
Set
DELAY
00 ~ 05 seconds
Set
OUTPUT
OFF, OUT1, OUT2
Set
HOLD TIME
03 ~ 99 seconds
Select “
AE SETUP
” and push the
Joystick
to the left or right. Then the AE setup displays.
Refer to the AE SETUP in the camera setup.
6. Set “
DWELL time
”. (03 ~ 99 seconds)
7. To select the next page of Presets, scroll the page by pushing the
Joystick
to the left or right on
the first or last columns of the menu.
8. Repeat step 2 through 7 for each additional Preset position.
9. Select “
SAVE AND EXIT
” and push the
Joystick
to the right or press the
IRIS Open
key. Press
the
ESC
or
IRIS Close
key to exit the program without saving.
NOTE: Press the HOME key at programmed Preset position (
*
) to delete a programmed
Preset view.
The position, which is marked with the
*
, already has the Preset view assigned. Press the
PRST
key on the
*
to review the stored Preset. The camera will show the stored Preset scene.
PRESET AREA SETUP
(CTRL KEY)
NUMBER 001
PAN TILT
000.0 000.0
EXIT(ESC TO EXIT)
Hold down the
CTRL
key while selecting the desired scene using the
Joystick
. Current position
will be displayed. Release the
CTRL
key to complete. Or press the
IRIS Open
key then the
“CONTROL” displays. Move the desired position and the zoom position. Press the
IRIS Close
key
then the “CONTROL” disappears. Select “EXIT” and push the
Joystick
to the right.