Dear Nüve User, 

We  would  like  to  take  this  opportunity  to  thank  you  for  preferring  this  Nüve  product.  Please 
read the operating instructions carefully and keep them handy for future reference. 

Please  detain  the  packing  material  until  you  see  that  the  unit  is  in  good  condition  and  it  is 
operating  properly.  If  an  external  or  internal  damage  is  observed,  contact  the  transportation 
company immediately and report the damage. According to ICC regulations, this responsibility 
belongs to the customer. 

While you are operating the instrument please; 

1.

 

obey all the warning labels, 

2.

 

do not remove the warning labels, 

3.

 

do not operate damaged instrument, 

4.

 

do not operate the instrument with a damaged cable, 

5.

 

do not move the instrument during operation. 

In case of a problem contact your Nüve agent for an authorized service or maintenance. 

The  validity  of  the  guarantee  is  subject  to  compliance  with  the  instructions  and  precautions 
described in this manual. 

Nüve reserves the right to improve or change the design of its products without any obligation 
to modify previously manufactured products. 

Information  contained  in  this  document  is  the  property  of  Nüve.  It  may  not  be  duplicated  or 
distributed without its permission. 

 

NÜVE  
SANAYİ MALZEMELERİ  
İMALAT VE TİCARET A.Ş. 

Saracalar Mahallesi, Saracalar Kümeevleri No:4/2 Akyurt 06750 ANKARA 
Ankara / TURKEY                            
Tel 

: (90.312) 399 28 30 (pbx)                                        

Fax 

: (90.312) 399 21 97                                                            

Sales  : [email protected]      
Technical Service: [email protected] 

Summary of Contents for EN 032

Page 1: ...N VE SANAY MALZEMELER MALAT VE T CARET A EN 032 EN 055 EN 120 INCUBATORS INSTRUCTION MANUAL Z14 K25 230 Rev No 03 Rev Date 01 2016...

Page 2: ...e damaged instrument 4 do not operate the instrument with a damaged cable 5 do not move the instrument during operation In case of a problem contact your N ve agent for an authorized service or mainte...

Page 3: ...nditions use of the product in non standard environmental conditions including but not limited to failure to meet requirements of ambient temperature lubrication humidity or magnetic field influences...

Page 4: ...UNPACKING 8 5 4 MAINS SUPPLY 8 5 5 POSITIONING 8 5 6 GENERAL PRESENTATION 9 5 7 CONTROL PANEL 10 5 8 PRIOR TO OPERATION 10 6 OPERATING PRINCIPLES 11 6 2 COMPLETION OF THE WORK 12 7 PERIODIC MAINTENANC...

Page 5: ...natural air circulation Stable and homogeneous temperature in the useful volume is provided by means of the forced air circulation through the stainless steel heaters placed onto the three outer surfa...

Page 6: ...ard maximum pcs 2 6 2 7 2 10 Power Consumption 300 W 350 W 400 W Power Supply 230 V 50 60 Hz Internal Material Stainless Steel External Material Epoxy polyester painted steel Internal Dimensions W x D...

Page 7: ...not destroy the structure of the samples Liquids are not heated in sealed containers The boiling points of the samples should be higher than the set temperature Liquids which may expand during heatin...

Page 8: ...h the instrument please check them 1 ea user s manual and warranty 1 ea electrical connection cable 2 ea shelves 4 ea shelf carriers 5 4 MAINS SUPPLY The instrument requires 230V 50 60 Hz Please make...

Page 9: ...pace between the equipment and wall 5 6 GENERAL PRESENTATION Figure 1 VENTILATION ADJUSTMENT BUTTON DISPLAY AND CONTROL PANEL DOOR HANDLE PLASTIC PADS ON OFF SWITCH FUSE HOLDER AND SUPPLY INLET VENTIL...

Page 10: ...Temperature Value Increase and Decrease Keys These keys are used to increase or decrease the values on the temperature display 7 Time Set Key This key is pushed to set the time 1 minute 99 9 hours an...

Page 11: ...key t n will appear on the temperature display Set the time value by pushing the value increase and decrease keys on the time adjustment side 1 minute to 99 9 hours Hold Push the time set key again t...

Page 12: ...maintenance 7 2 CLEANING Clean the incubator and at room temperature after disconnecting the power cable Clean the incubator with a wet cloth to remove dirt and dust Use liquid detergent to remove tou...

Page 13: ...properly The installation of the plug is not defective The mains supply is present If the incubator does not heat check the followings The program is started The safety thermostat value is adjusted hi...

Page 14: ...14 10 ELECTRICAL CIRCUIT DIAGRAM 10 1 ELECTRICAL CIRCUIT DIAGRAM FOR EN 032 10 2 ELECTRICAL CIRCUIT DIAGRAM FOR EN 055 AND EN 120 HEATERS EN 055 2 x 700 W EN 120 2 x 800 W...

Reviews: