Open
Vertical
Electric
21
www.nuvair.com
13.0 Maintenance
13.1 Foreword
To obtain the best possible performance from the compressor and ensure a long working life
for all its parts it is essential that personnel follow the use and maintenance instructions with
extreme diligence. It is thus advisable to read the information below and consult the manual
every time an inconvenience arises. For further information please contact Nuvair
Nuvair
Address:
Phone
: +1 805 815 4044
1600 Beacon Place
Email:
Oxnard, California 93033, USA
13.2 General
Proper preservation of the compressor requires thorough cleaning.
This type of refill station, designed and built according to the most advanced
technological criteria, requires only minimum preventive and routine maintenance.
Before carrying out any maintenance tasks, run checks and/or controls on the
compressor, switch off the compressor, remove the plug from the mains socket.
The residual pressure present in the compressor and all lines must be released.
During disassembly and re-assembly of the compressor, always use suitable
wrenches/tools so as not to damage the relevant components.
Loosen stiff parts with a copper or plastic mallet.
When refitting parts make sure they are clean and lubricated sufficiently.
Compressor maintenance tasks must only be carried out by authorized personnel and
recorded on page 31 Maintenance Log of this manual.
13.3 Unscheduled Work
Involves repairs and/or replacement of the mechanical parts of one or more compressor
components, this work normally needs to be done after some years of use. If substantial
modifications are made, the manufacturer cannot be held liable for any dangers that might
arise. This work must be carried out by a “Nuvair” qualified mechanic.
13.4 Scheduled Maintenance Table
Maintenance
Every
5 hours
Every
Day
Every
Year
250
(hours)
500
(hours)
1000
(hours)
3000
(hours)
Lubricating Oil Check
Automatic Shutdown Check
Condensate Container discharge
Belt wear and tension
Air intake filter
Fitting / hose leak check
Oil (and filter) change
Separator filter element cleaning
1
st
– 2
nd
– 3
rd
stage Valve replacement
Water & HP oil separator replacement
HP filter body replacement
Checking and cleaning
Change