background image

5

OPERATION AND MAINTENANCE (

CONT

D

)

SEALED HEPA PERMANENT FILTER 
(PP600 AND PP650 POWER UNITS ONLY)

This filter protects the motor and stops small particles from escaping to the outside of the 

power unit without the need to replace it. The filter cleans itself by moving up when the power 

unit starts, and dropping down when the unit is turned off. Under normal use, there is no need 

to maintain this filter. It is possible to remove it to inspect the foam motor filter, or to replace it 

if ever it has been damaged (by sharp debris, for example). 

REMOVAL AND INSTALLATION OF SEALED HEPA PERMANENT 
FILTER (PP600 AND PP650 POWER UNITS ONLY)

To remove:

Remove the pail from the unit. To remove the
permanent filter, use pull tab (

A

) located on edge of

filter to pull and loosen filter from inlet chamber wall.
Squeeze from both sides of the filter to the center of
the housing (see illustration at right). Then, carefully
remove it from the unit.

To reinstall:

Squeeze the filter in order to move it past the inlet
opening (

B

) (see illustration at right). Let the filter bear 

against the unit wall by releasing the pressure. Make
sure to place the rigid ring in its groove to ensure
proper sealing.

NOTE:  Make sure the filter is installed so that the 

pull tab (

A

) is accessible for future filter removal.

AD0084

A

AA0005

A

CAUTION

Be sure to reinstall filter properly. Appropriate location is critical to insure 
proper protection of the motor.

AD0085

B

Summary of Contents for PP500

Page 1: ...USER GUIDE CENTRAL VACUUM POWER UNITS PP500 PP600 PP650 AB0039 FOR RESIDENTIAL USE ONLY 30042509E MODELS SFDB DQ SFDB DR AND SFDB DS PUREPOWER SERIES...

Page 2: ...ning blocked keep free of dust lint hair and anything that may reduce air flow 2 Ensure air flows freely and exhausts unobstructed from top or side outlet 3 Do not use without filter or filters accord...

Page 3: ...has a grounding attachment plug that looks like the plug shown in illustration below No adapter should be used with this power unit NOTE Inlet leads to be connected to power unit low voltage tabs usi...

Page 4: ...oss of suction is caused by a blockage in the system changing the bag or emptying the debris pail will solve the problem NOTE Even if not filled to capacity if the bag seems tightly stretched when rem...

Page 5: ...POWER UNITS ONLY To remove Remove the pail from the unit To remove the permanent filter use pull tab A located on edge of filter to pull and loosen filter from inlet chamber wall Squeeze from both sid...

Page 6: ...removed PP600 and PP650 units only Simply brush filter clean If the filter is excessively soiled hand wash in a water and mild detergent solution rinse and let it dry completely on a flat surface befo...

Page 7: ...art and pulling on upper part to disengage it NOTE A small flat blade screwdriver can also be used to pry on the 4 retaining tabs as shown in illustration A at the bottom of the page Discard the used...

Page 8: ...SERVICE PARTS PP650 UNIT PP500 AND PP600 UNITS 8 AL0021 7 15 10 17 8 9 11 1 3 12 13 14 1 2 4 5 6 16...

Page 9: ...P CAP ASSEMBLY 1 S10941411 PP500 TOP CAP ASSEMBLY 1 2 S10941416 PP650 EXHAUST HEPA FILTER 1 3 S10941413 PP650 TOP CAP ASSEMBLY INCLUDING ITEM 5 LOWER PART 1 4 S10941419 MOTOR WITH UPPER AND LOWER FOAM...

Page 10: ...sable bag torn Wall inlet cover not properly sealed Exhaust tubing or vent clogged Change the disposable bag or empty debris pail as described on page 5 Replace the debris pail gasket Disconnect the h...

Page 11: ...as occured somewhere in the system Set the unit power switch to OFF position Perform a complete check of all wall inlets and power unit low voltage control leads connections Contact your authorized Se...

Reviews: