SAVE THESE  INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

WARNING

To reduce the risk of fire, electric 
shock or injury:

1.

Do not use on wet surfaces or outdoors.

2.

Do not vacuum liquids or fine powders
(such as drywall dust).

3.

Do not use to pick up flammable or
combustible liquids such as gasoline or
use in areas where they may be present.

4.

Do not pick up anything that is burning or 
smoking, such as cigarettes, matches, or
hot ashes.

5.

Do not allow to be used as a toy. Close
attention is necessary when used by or
near children.

6.

Use only as described in this manual.
Use only manufacturer's recommended
attachments.

7.

Keep hair, loose clothing, fingers and all
parts of body away from openings and
moving parts.

8.

Turn off all controls before unplugging.

9.

Use extra care when cleaning on stairs.

10.

Do not handle plug or appliance with wet
hands.

11.

Do not use with damaged cord or plug.
If appliance is not working as it should,
if it has been dropped, damaged, left
outdoors, or dropped into water, return it
to a Service Center.

12.

Keep your work area well lighted.

13.

Connect to a properly grounded outlet
only. See grounding instructions shown
on page

 

3.

14.

When performing installation, servicing
or cleaning the unit, it is recommended
to wear safety glasses and gloves.

CAUTION

1.

Do not put any object into openings. Do
not use with any opening blocked; keep
free of dust, lint, hair and anything that
may reduce air flow.

2.

Ensure air flows freely and exhausts
unobstructed from top or side outlet.

3.

Do not use without filter (or filters,
according to the model) in place.

4.

Do not use to blow leaves or debris.

5.

Do not place any object on top of the unit.

6.

Do not install the unit horizontally.

7.

Do not use the pail as a wash bucket.

8.

Do not use the pail as a stool.

9.

Avoid picking up sharp objects. 

10.

This appliance is for use on a standard
120 VAC, dedicated 20-amp minimum
branch circuit.

11.

Do not unplug the unit by pulling on cord. 
To unplug, grasp the plug, not the cord.

12.

 Store your vacuum cleaner indoors in

a clean, dry area, away from extreme
temperatures.

13.

 

Any servicing other than that
recommended in this manual should
be performed by an authorized service
facility.

14.

 

We recommend that your unit be
inspected by a specialized technician
once a year.

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be 

followed, including the following:

2

GROUNDING INSTRUCTIONS  . . . .  3

OPERATION & MAINTENANCE  . .4-7

W

HEN

 

TO

 

CHANGE

 

BAG

 

OR

 

EMPTY

 

DEBRIS

 

PAIL

 . . . . . . . . . . . . . . . 4

 

H

OW

 

TO

 

EMPTY

 

DEBRIS

 

PAIL

 (PP600 

AND

 

 PP650 

POWER

 

UNITS

 

ONLY

) . . . . . . . . . . . 4

 

D

ISPOSABLE

 

BAG

 

REPLACEMENT

 

 (M

ODEL

 395) . . . . . . . . . . . . . . . . . . . . . 4

 

S

EALED

 HEPA P

ERMANENT

 

FILTER

 

 (PP600 

AND

 PP650 

POWER

 

UNITS

 

ONLY

)  . 5

 

R

EMOVAL

 & 

INSTALLATION

 

OF

 

PERMANENT

 

FILTER

(PP600 & PP650 

POWER

 

UNITS

 

ONLY

) . . . 5

 

M

OTOR

 

FOAM

 

FILTER

 (

ALL

 

UNITS

)  . . . . . . . . 6

 

R

EMOVAL

 & I

NSTALLATION

 

OF

 S

ECONDARY

 

 HEPA 

F

ILTER

 (PP650 P

OWER

 U

NIT

 O

NLY

) 7

SERVICE PARTS  . . . . . . . . . . . . . .8-9

TROUBLESHOOTING GUIDE . . 10-11

TABLE OF CONTENTS

Summary of Contents for PP500

Page 1: ...USER GUIDE CENTRAL VACUUM POWER UNITS PP500 PP600 PP650 AB0039 FOR RESIDENTIAL USE ONLY 30042509E MODELS SFDB DQ SFDB DR AND SFDB DS PUREPOWER SERIES...

Page 2: ...ning blocked keep free of dust lint hair and anything that may reduce air flow 2 Ensure air flows freely and exhausts unobstructed from top or side outlet 3 Do not use without filter or filters accord...

Page 3: ...has a grounding attachment plug that looks like the plug shown in illustration below No adapter should be used with this power unit NOTE Inlet leads to be connected to power unit low voltage tabs usi...

Page 4: ...oss of suction is caused by a blockage in the system changing the bag or emptying the debris pail will solve the problem NOTE Even if not filled to capacity if the bag seems tightly stretched when rem...

Page 5: ...POWER UNITS ONLY To remove Remove the pail from the unit To remove the permanent filter use pull tab A located on edge of filter to pull and loosen filter from inlet chamber wall Squeeze from both sid...

Page 6: ...removed PP600 and PP650 units only Simply brush filter clean If the filter is excessively soiled hand wash in a water and mild detergent solution rinse and let it dry completely on a flat surface befo...

Page 7: ...art and pulling on upper part to disengage it NOTE A small flat blade screwdriver can also be used to pry on the 4 retaining tabs as shown in illustration A at the bottom of the page Discard the used...

Page 8: ...SERVICE PARTS PP650 UNIT PP500 AND PP600 UNITS 8 AL0021 7 15 10 17 8 9 11 1 3 12 13 14 1 2 4 5 6 16...

Page 9: ...P CAP ASSEMBLY 1 S10941411 PP500 TOP CAP ASSEMBLY 1 2 S10941416 PP650 EXHAUST HEPA FILTER 1 3 S10941413 PP650 TOP CAP ASSEMBLY INCLUDING ITEM 5 LOWER PART 1 4 S10941419 MOTOR WITH UPPER AND LOWER FOAM...

Page 10: ...sable bag torn Wall inlet cover not properly sealed Exhaust tubing or vent clogged Change the disposable bag or empty debris pail as described on page 5 Replace the debris pail gasket Disconnect the h...

Page 11: ...as occured somewhere in the system Set the unit power switch to OFF position Perform a complete check of all wall inlets and power unit low voltage control leads connections Contact your authorized Se...