NuTone PP500 User Manual Download Page 4

Open the inlet cover and insert the end of the hose into the inlet to turn on the vacuum. 

For non-switched hoses, inserting the hose automatically turns on the power unit; removing 
the hose shuts off the power unit. Some hoses have switches which can be used to activate 
power unit. Unless using the utility valve (PP650 unit only) the ON/OFF switch located on the 
power unit needs to be kept in the OFF position.

As you vacuum, dirt and dust are carried to the power unit where they remain in a bag or in 
the debris pail (according to the power unit model).

Use the cleaning tools as you would for any other vacuum cleaner. Avoid picking up very large 

debris or lengthy as these kinds of objects may become lodged in the hose or tubing.

WHEN TO CHANGE BAG OR EMPTY DEBRIS PAIL

With a 6 U.S. gallons capacity, under normal conditions the bag/debris pail requires changing/

emptying approximately twice a year. If the bag/debris pail is full, you will notice a reduced 

suction from the system. Unless this loss of suction is caused by a blockage in the system, 

changing the bag or emptying the debris pail will solve the problem.

NOTE: 

Even if not filled to capacity, if the bag seems tightly stretched when removing the 

debris pail, changing the bag will prevent it from tearing.

HOW TO EMPTY DEBRIS PAIL 
(PP600 AND PP650 POWER UNITS ONLY)

To empty the debris pail, release both latches on sides of the unit by pulling out and then 
pushing up. Holding the pail by the latches, lower it from unit. Carry pail to trash receptacle 
and dispose of debris. Put the pail back in its place.

DISPOSABLE BAG REPLACEMENT (MODEL 391)

To remove the disposable bag, release both latches on sides of the unit by pulling out and
then pushing up. Remove the pail from unit. Grasp the edges of the bag collar and pull
down. The bag will slide off easily. Do not pull on the bag.

Unfold the new bag.

 

Grasp collar where indicated on the new bag and insert over bag adapter. Be careful not 
to tear the bag. Ensure the collar is positioned between the taper ring and the bag stopper 
on the bag adapter (see illustration below). Put the pail back in its place.

OPERATION AND MAINTENANCE

AO0081

T

APER

 

RING

B

AG

 

STOPPER

4

D

ISPOSABLE

 

BAG

 

MODEL

 391

Summary of Contents for PP500

Page 1: ...USER GUIDE CENTRAL VACUUM POWER UNITS PP500 PP600 PP650 AB0039 FOR RESIDENTIAL USE ONLY 30042509E MODELS SFDB DQ SFDB DR AND SFDB DS PUREPOWER SERIES...

Page 2: ...ning blocked keep free of dust lint hair and anything that may reduce air flow 2 Ensure air flows freely and exhausts unobstructed from top or side outlet 3 Do not use without filter or filters accord...

Page 3: ...has a grounding attachment plug that looks like the plug shown in illustration below No adapter should be used with this power unit NOTE Inlet leads to be connected to power unit low voltage tabs usi...

Page 4: ...oss of suction is caused by a blockage in the system changing the bag or emptying the debris pail will solve the problem NOTE Even if not filled to capacity if the bag seems tightly stretched when rem...

Page 5: ...POWER UNITS ONLY To remove Remove the pail from the unit To remove the permanent filter use pull tab A located on edge of filter to pull and loosen filter from inlet chamber wall Squeeze from both sid...

Page 6: ...removed PP600 and PP650 units only Simply brush filter clean If the filter is excessively soiled hand wash in a water and mild detergent solution rinse and let it dry completely on a flat surface befo...

Page 7: ...art and pulling on upper part to disengage it NOTE A small flat blade screwdriver can also be used to pry on the 4 retaining tabs as shown in illustration A at the bottom of the page Discard the used...

Page 8: ...SERVICE PARTS PP650 UNIT PP500 AND PP600 UNITS 8 AL0021 7 15 10 17 8 9 11 1 3 12 13 14 1 2 4 5 6 16...

Page 9: ...P CAP ASSEMBLY 1 S10941411 PP500 TOP CAP ASSEMBLY 1 2 S10941416 PP650 EXHAUST HEPA FILTER 1 3 S10941413 PP650 TOP CAP ASSEMBLY INCLUDING ITEM 5 LOWER PART 1 4 S10941419 MOTOR WITH UPPER AND LOWER FOAM...

Page 10: ...sable bag torn Wall inlet cover not properly sealed Exhaust tubing or vent clogged Change the disposable bag or empty debris pail as described on page 5 Replace the debris pail gasket Disconnect the h...

Page 11: ...as occured somewhere in the system Set the unit power switch to OFF position Perform a complete check of all wall inlets and power unit low voltage control leads connections Contact your authorized Se...