background image

INST

ALLA

TION 

AND USE & CARE INSTR

UCTIONS

 

INST

ALLA

TION

3

OPTION -

 To mount housing anywhere between ceiling framing: 

Use optional Hanger Bar Kit (sold separately from local distributors or 

website). Follow mounting instructions included with kit.

1.  Remove blower and all packing 

material from fan housing.

2.  Remove wiring panel from 

fan housing.

ROOF CAP * (with built-in damper)

WALL CAP *

(with built-in

damper)

4-IN. ROUND

ELBOWS *

FAN

HOUSING

Seal gaps

around

housing.

Seal duct joints

with tape.

INSULATION

(Place around and

over fan housing.)

POWER

CABLE *

* Purchase separately.

OR

Keep duct

runs short.

4-IN. ROUND

DUCT *

ALL INSTALLATIONS

Start here.

IMPORTANT -

 The ducting from this fan to the outside 

of the building has a strong effect on the air flow, noise and 

energy use of the fan. Use the shortest, straightest duct routing 

possible for best performance, and avoid installing the fan with 

smaller ducts than recommended. Insulation around the ducts 

can reduce energy loss and inhibit mold growth. Fans installed 

with existing ducts may not achieve their rated airflow.

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

4.  Attach grille brackets to 

housing.

3.  A pair of flanges may be 

attached to housing if 

desired or required.

Snap both flange pieces under rolled-over edge 

of housing (all four sides).

Summary of Contents for AER110LTK

Page 1: ...D USE CARE INSTRUCTIONS INSTRUCTIONS D INSTALLATION D UTILISATION ET D ENTRETIEN INSTRUCCIONES DE INSTALACI N USO Y CUIDADO English See page 2 Fran ais Voir page 7 Espa ol Consulte la p gina 12 ROOMSI...

Page 2: ...ccordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney...

Page 3: ...uns short 4 IN ROUND DUCT ALL INSTALLATIONS Start here IMPORTANT The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the sh...

Page 4: ...sing Push connector through opening from inside of housing Engage tabs and secure with screw from parts bag 6 Mount housing to ceiling structure Make sure bottom of housing will be flush with finished...

Page 5: ...included Squeeze 2 GRILLE SPRINGS and insert them into 2 GRILLE SPRING TABS Push GRILLE FRAME up against the ceiling 9 Install blower Re install blower Secure blower with 2 screws from parts bag and p...

Page 6: ...Wiring Diagram section Re install wiring panel and secure with screw from parts bag 9 Connect 4 in round duct Pull existing ducting through housing discharge opening Attach and tape ducting to duct c...

Page 7: ...is ceux concernant la protection contre les incendies Un certain volume d air est n cessaire aux appareils combustible pour assurer la bonne combustion et l vacuation des gaz par le conduit de fum e c...

Page 8: ...ATIONS D but IMPORTANT Le conduit reliant l appareil l ext rieur influe fortement sur le d bit d air le bruit et la consommation d nergie de l appareil Pour une performance optimale suivre le trac de...

Page 9: ...de l int rieur du bo tier Placer les languettes et fixer le raccord avec des vis du sac de pi ces 6 Fixer le bo tier la charpente du plafond Veiller ce que le bas du bo tier affleure la surface finie...

Page 10: ...ns rer dans les deux 2 ATTACHES DES RESSORTS DE GRILLE Pousser le CADRE DE GRILLE contre le plafond 9 Installer le ventilateur Replacer le ventilateur Le fixer avec deux 2 vis du sac de pi ces et bran...

Page 11: ...blage et le fixer avec des vis du sac de pi ces 9 Raccorder le conduit rond de 4 po Tirer le conduit existant travers l ouverture d vacuation du bo tier Joindre le conduit au raccord et fixer le join...

Page 12: ...mas de construcci n espec ficos sobre protecci n contra incendios Es necesario suficiente aire para que se lleve a cabo una combusti n y una extracci n adecuadas de los gases a trav s del tubo de humo...

Page 13: ...ntenga cortos los tramos de conductos 4 pulg 10 cm CONDUCTO REDONDO TODAS LAS INSTALACIONES Comience aqu IMPORTANTE Los conductos desde este ventilador hacia el exterior del edificio tienen un gran ef...

Page 14: ...e el interior de la cubierta Enganche las leng etas y f jelas con el tornillo incluido en la bolsa de piezas 6 Monte la cubierta en la estructura del cielo raso Aseg rese de que la parte inferior de l...

Page 15: ...ETAS PARA RESORTE DE REJILLA Empuje el MARCO DE LA REJILLA contra el cielo raso 9 Instale el soplador Vuelva a instalar el soplador File el soplador con 2 tornillos de la bolsa de piezas y conecte el...

Page 16: ...elo con el tornillo de la bolsa de piezas 9 Conecte el conducto redondo de 4 pulg 10 cm Pase el conducto existente por la abertura de descarga de la cubierta Fije y pegue con cinta los conductos al co...